CYP PU-507RX-SCD Kullanım Kılavuzu - Sayfa 12
Alıcı CYP PU-507RX-SCD için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. CYP PU-507RX-SCD 20 sayfaları. 5-play hdbaset receiver with integrated video scaling
& audio breakout (inc. poe & single lan, up to 100m) -
stereo audio only
Ayrıca CYP PU-507RX-SCD için: Kullanım Kılavuzu (18 sayfalar)
COMMAND
S SATURATION 0~60
R SATURATION
S SHARPNESS 0~30
R SHARPNESS
S NR 0~3
R NR
S AUDIO DELAY 0~3
R AUDIO DELAY
S AUDIO MUTE 0/1
R AUDIO MUTE
S KEY LOCK 0/1
R KEY LOCK
FW
S RESET 1
Note:
1. RS-232 commands will not execute unless followed with carriage return
and LF (Line Feed).
2. Commands are case-insensitive.
3. Resolutions 1~16 are RGB encoded and 17~25 are YUV encoded.
4. Digital audio supports LPCM 2CH only, please ensure the source input audio
is set to send LPCM 2CH audio in order to avoid unwanted audio noise.
12
DESCRIPTION
Sets the numerical value for the
SATURATION setting (0~60)
Reports the numerical value for the
SATURATION setting (0~60)
Sets the numerical value for the
SHARPNESS setting (0~30)
Reports the numerical value for the
SHARPNESS setting (0~30)
0=OFF
1=LOW
Reports the numerical equivalent for the
NOISE REDUCTION setting (as listed above)
0=OFF
1=40ms
Reports the numeric equivalent for AUDIO
DELAY setting (as listed above)
0=ON
Reports the numeric equivalent for AUDIO
MUTE setting (as listed above)
0=ENABLE
Reports the numeric equivalent for KEY
LOCK setting (as listed above)
Checks the FIRMWARE version
Sets the numerical equivalent for the RESET
setting (as left)
2=MIDDLE
3=HIGH
2=110ms
3=150ms
1=MUTE
1=DISABLE