Technical Data
Phase / motor
voltage L1/L2/L3:
Nominal frequency:
Nominal motor power P
at 400 V:
N
Switching frequency
, 5 s, ϑ
at 3 x I
= 45°C:
N
U
permissable braking current:
Min. motor power:
Start torque:
Ramp time:
Braking time:
Braking delay:
Braking voltage:
Start delay:
Auxiliary voltage U
H
Model DC 24 V:
Model AC 230 V:
Model AC 400 V:
Power consumption:
Residual ripple max.:
Max. semiconductor fuse
BL 9228 / 7.5 kW:
BL 9228 / 11 kW:
BL 9228 / 15 kW:
Inputs
Control input X1, X2
Voltage.
Input P
/ P
for
2
3
bimetallic contact
Current:
Voltage:
Input P
/ P
for PTC-sensor
1
2
Temperature sensor:
Number of sensors:
Response value:
Reset value:
Load in measuring circuit:
Broken wire detection:
Measuring voltage:
Measuring current:
Voltage, when broken
wire in sensor circuit:
Current, when short
circuit in sensor circuit:
Monitoring Output
Contacts:
Thermal continous
current I
:
th
Switching capacity
to AC 15
NO contact:
Electrical life
to AC 15 at 3 A,
AC 400 V:
Short circuit strength
max. fuse rating:
General Data
Temperature range:
Storage temperature:
Clearance and creepage
distances
rated impuls voltage /
pollution degree
Control voltage to auxiliary
voltage, motor voltage:
Auxiliary voltage to
motor voltage:
3 AC 200 V -10 % ... 480 V + 10 %
50 / 60 Hz
Width
90 mm
112.5 mm 112.5 mm
7.5 kW
11 kW
15 kW
10 / h
45 / h
30 / h
35 A
50 A
65 A
1 kW
20 ... 80 %
1 ... 20 s
1 ... 15 s
max. 2500 ms
DC 10 ... 90 V
450 ms
A1/A2, DC 24 V, + 10 %, - 10 %
A1/A2, AC 230 V, + 10 %, - 15 %
A1/A2, AC 400 V, + 10 %, - 15 %
2 W
5 %
1800 A
s
2
6600 A
s
2
18050 A
s
2
DC 24 V
Approx. 1 mA (= switch closed)
Approx. 5 V (= switch open)
PTC-sensor according to DIN 44081/082
1 ... 6 in series
3.2 ... 3.8 kΩ
1.5 ... 1.8 kΩ
< 5 mW (at R = 1.5 kΩ)
> 3.1 kΩ
≤ 2 V (at R = 1.5 kΩ)
≤ 1 mA (at R = 1.5 kΩ)
DC approx. 5 V
DC approx. 0.5 mA
4 x 1 NO contacts
4 A
3 A / 400 V
IEC/EN 60947-5-1
2 x 10
switching cycles
5
IEC/EN 60947-5-1
4 A gG / gL
IEC/EN 60947-5-1
0 ... + 45 °C
- 25 ... + 75 °C
4 kV / 2
IEC 60664-1
4 kV / 2
IEC 60664-1
Technical Data
EMC
Electrostatic discharge:
HF-irradiation:
Fast transients:
Surge voltages
between
wire for power supply:
Between wire and ground:
Degree of protection
Housing:
Terminals:
Vibration resistance:
Climate resistance:
Wire connection
Load terminals:
Control terminals:
Wire fixing
Load terminals:
Control terminals:
Mounting:
Weight
Width 90 mm:
Width 112.5 mm:
Dimensions
Width x height x depth
BL 9228 up to 7.5 kW:
BL 9228 up to 15 kW:
Standard Type
BL 9228.03/010 3 AC 200 ... 480 V 50/60 Hz U
Article number:
• Nominal motor power
at AC 400 V:
• Control input X1, X2
• Width:
Ordering example:
BL 9228. 03/_ _ _ 3 AC 200...480 V
3
8 kV (air)
IEC/EN 61000-4-2
10 V
IEC/EN 61000-4-3
2 kV
IEC/EN 61000-4-4
1 kV
IEC/EN 61000-4-5
2 kV
IEC/EN 61000-4-5
IP 40
IEC/EN 60529
IP 20
IEC/EN 60529
Amplitude 0.35 mm
frequency 10 ... 55 Hz, IEC/EN 60068-2-6
0 / 055 / 04
IEC/EN 60068-1
1 x 10 mm
solid
2
1 x 6 mm
stranded ferruled
2
1 x 4 mm
solid or
2
1 x 2.5 mm
stranded ferruled (isolated) or
2
2 x 1.5 mm
stranded ferruled (isolated)
2
DIN 46228-1/-2/-3/-4 or
2 x 2.5 mm
stranded ferruled
2
DIN 46228-1/-2/-3
Plus-minus terminal screws M4
box terminals with wire protection
Plus-minus terminal screws M3.5
box terminals with wire protection
DIN rail mounting
IEC/EN 60715
895 g
1135 g
90 x 85 x 121 mm
112.5 x 85 x 121 mm
DC 24 V 15 kW
H
0064256
15 kW
112.5 mm
50/60 Hz U
DC 24 V 15 kW
H
Auxiliary/control voltage
Nominal motor power
at AC 400 V
Nominal frequency
Phase/motor voltage
Variants, if required
0 = Standard
0 = Standard
1 = Input P1/P2/P3
for motor temperatur
monitoring
0 = With standstill
monitoring
1 = Without standstill
monitoring; braking
time adjustable on
potentiometer
Contacts
Type