Ashly CA-1.54 Kullanım Kılavuzu - Sayfa 9
Amplifikatör Ashly CA-1.54 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Ashly CA-1.54 12 sayfaları. 2- and 4-channel
CA Amplifier • Operating Manual
(rear panel features continued)
5.7
Combo Input Jack
The combination 1/4" TRS and XLR jack (pin 2
hot) is wired in parallel to the Euroblock input.
Do not float the TRS ring or XLR pin 3, connect
it to (-) signal or to ground (if unbalanced).
5.8
Speaker Output Connectors
7.62mm Euroblock connectors are used for
convenient and secure wiring to speaker
loads. Bridge mode uses the center two pins as
indicated on the amplifier back panel.
5.9
AC Mains Connector
Always use the AC cord provided by Ashly
for connecting to mains power. The amplifier
auto-detects mains voltage from 100VAC to
240VAC. WARNING: Do not remove or lift the
mains connector ground.
5.10
Serial Number Sticker
This sticker identifies the product model
number, serial number, and AC mains current/
power rating.
6
Troubleshooting
No AC Power
•
Is the detachable AC power cord properly
installed? Is it plugged into a known live
outlet?
•
Has the power switch been disabled?
No Amplifier Output
•
Is the amplifier in Standby Mode?
•
Is there signal getting to the amplifier?
•
Is the input signal properly wired?
•
Are output connectors properly wired?
•
Are front panel or remote control attenuators
turned down?
•
Is the Amplifier in Protect Mode? (see table
below)
Protect Mode - Front Panel LED Error Codes:
Protect Mode Fault Description
>9dB Continuous Power Limiting
Amp Power Module Channel Protect
Thermal Protect
†
Power Supply Out Of Range
††
*Amp Channel DC Protect
*Amp Channel Over-Temperature
*Power Transformer Over-Temperature
*Power Supply Rails Too High
*Micro-Controller Over-Temperature
Thermal Protect
†
Power Supply Out Of Range
††
*Amp Channel DC Protect
*Amp Channel Over-Temperature
*Power Transformer Over-Temperature
*Power Supply Rails Too High
*Micro-Controller Over-Temperature
Amp still passes audio, automatic recovery
†
Amp mutes until fault clears, automatic recovery
††
* Non-recoverable fault, must reset Amp by cycling AC power
Attenuators Don't Work
•
Have the front panel controls been disabled
using the rear panel DIP switch?
Still Not Working?
•
Contact Ashly technical support at 1-800-
872-0010 x124, or email [email protected]
Power
Protect Clip/Mute Signal Temp Current
On
On
On
On
On
On
On
On
On
Standby
Standby
Standby
Standby
Standby
Standby
Standby
9