Ambirad TORNADO Посібник з монтажу та експлуатації - Сторінка 6
Переглянути онлайн або завантажити pdf Посібник з монтажу та експлуатації для Газовий обігрівач Ambirad TORNADO. Ambirad TORNADO 16 сторінок. Gas fired mobile heater
Також для Ambirad TORNADO: Інструкція з експлуатації (8 сторінок)
Note When positioning the heater please ensure
that all inlets and outlets are unrestricted there are
no combustible materials in the vicinity. Please
ensure the heated air is not directed towards the
gas bottle.
In dusty environments the fresh air
duct must be used. See section 4.
4.3 Thermostat Control
The temperature of the building can be controlled
using an optional remote thermostat. A remote
thermostat kit c/w 5 metres of cable is available
from Ambi-Rad by quoting part number 200587.
Select remote thermostat.
Plug the remote stat lead into the remote stat
socket.
4.3 Operation
After switching on the mains supply, ignition is
controlled
by
the
incorporated on the burner assembly.
Firstly
you
will
hear
convection fans running. ( Note - If the
automatic
ignition
the
combustion
combustion fan does not operate, then check to
see if the overheat stat reset has tripped. This is
located behind the combustion fan access door -
see 7.3)
Then, after a delay of 15-20 seconds, you will
hear a 'Clicking' noise, as the igniter assembly
attempts to light the gas. On ignition the amber
light will illuminate. If ignition does not occur then
the light turns off indicating there is potentially air
in the gas line.
Re-ignition can be attempted by restarting the ap-
pliance. If ignition still does not occur and the
lockout lamp illuminates, it is likely that the low
gas pressure switch is activated indicating that the
LPG bottles are exhausted of gas and require
changing. If after changing the gas bottles and
ignition still cannot be achieved, please refer to
section 8.1 Fault Finding.
4.4 Disconnection
Note Connecting and disconnecting cylinders
MUST take place in a flame free atmosphere.
When the appliance is not going to be used for a
period of time the unit MUST be disconnected
from the electrical mains and gas cylinder.
When heating is complete, turn OFF the gas
supply. Leave the electric supply turned ON to
enable the combustion fan to operate for 10
minutes to cool the product prior to moving.
After cooling is complete, switch the 3 position
rocker switch on the rear of the product to the
OFF position and disconnect from the electric
supply and remove the electrical connector.
Disconnect the gas supply and recoil the hose
around the rear ring assembly..
Note If the appliance is not to be used for a period
of time, ensure that the appliance is stored in a
dry environment.
5.0 Cleaning & Maintenance
The gas hose should be checked regularly for its
integrity, if any damage is found the hose must be
replaced. See Technical details for hose details.
Ensure that the air intakes and flue outlet on the
sides of the product are clean and free from any
unit
blockage.
The casing can be cleaned with a soft cloth and a
and