Figure 4: GFCI Outlet
DANGER: Improper installation of the grounding
plug can result in a risk of electric shock.
Do not modify the plug provided; if it will not fit the outlet, have the
proper outlet installed by a qualified electrician. This product is for use
on a nominal 120-volt circuit. No adapter should be used with this
product. This product has an automatic thermal limiter, which shuts
off the entire product when an elevated temperature condition exists.
When the product cools it will automatically restart. Only if required,
obtain a UL outdoor rated extension cord. Never locate the Aero-Spa
generator closer than 10' from the hot tub. In the event of a power
outage, the GFCI device will need to be reset manually.
Occasionally GFCI breakers will experience nuisance tripping. This
will shut off the power to the equipment. If this occurs, press the
"reset" button. If pressing the "reset" button does not start the
equipment, unplug the cycle timer and press the "reset" button again.
If the "reset" button does not "hold in", replace the GFCI breaker. If
the button does "hold in", plug the generator power cord into the GFCI
breaker and circumvent the cycle timer. Press the "reset" button
again. If the "reset" button does not "hold in" replace the GFCI
breaker. If the "reset" button does "hold in" contact Aero-Spa™.
Do not operate this equipment without a GFCI breaker installed.
© Copyright Aero-Spa®, LLC 2021 REV H