Dontek AQUASMART 5 SV Інструкція з експлуатації - Сторінка 8

Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Контролер Dontek AQUASMART 5 SV. Dontek AQUASMART 5 SV 13 сторінок.

OFF
(RANGE = OFF-20 MINUTES)
Once the heater achieves temperature or if the heating time period ends then the
HEATER COOL
heater is switched off. The cool down timer ensures that the circulation pump
DOWN?
continues to operate to cool the heater before the pump switches off.
If the 'use solar valve' option is selected, a reduced cool-down (1 min) is used before a
valve turn (a full cool-down still occurs before the circulation pump is switched off).
INLINE WITH SOLAR/PARALLEL WITH SOL
Heater configuration tells the controller where the heater is located in the return water
path (see diagram on pg4). The normal path is for the solar to return through the heater
back into the pool (heater is located in the return line after the solar collector 'T'
junction). This is called INLINE WITH SOLAR.
HEATER CONFIG?
If water from the solar collectors returns to the pool without going through the heater,
select PARALLEL WITH SOLAR.
Note: The heater will not operate in conjunction with solar when the configuration is
set to Parallel.
ROOF TEMPERATURE
START DIFF x.x° (4.0°-40.0°C)
ROOF TEMPERATURE
STOP DIFF x.x° (1.0°-(START -2°C))
ROOF TEMPERATURE
MIN. ROOF xx.x° (OFF,10.0°-60.0°C)
ROOF
You can modify the differentials. The Start differential is the temperature the roof
TEMPERATURE?
needs to rise above the pool to start the pump.
The Stop differential stops the pump when the roof drops below the pool temp plus the
stop differential.
Minimum roof is the roof temperature required for the solar to start heating (Off =
feature disabled).
Ensure that the filtration pump is plugged into the outlet labelled as PUMP and the
Sanitiser is plugged into the SANITISER power outlet of the controller.
The controller will ask you if you would like the current detection to be ON or OFF. Use
the ↑ or ↓ buttons to select the required option and press the Enter button.
If OFF is selected the unit will operate as a standalone solar controller and the PUMP
socket will be powered constantly.
Note: The valve actuator may open in this instance (due to there being solar gain) even
if no water is flowing through the system (ie out of heating time).
If ON is selected then the filtration pump will start.
Ensure the filtration pump is operating (and at the required speed for variable speed
PRIME PROTECT?
pumps) via the controller's PUMP socket and is primed, then use the
YES/NO
select either SET AUTO or SET MAN and press the Enter button.
If you select SET AUTO - the unit will display the pump's load value for 5 seconds then
automatically sets the threshold levels and returns to automatic operation. If the
current draw of the filtration pump drops below the selected threshold levels then the
solar pump is forced to switch off.
If you select SET MAN. - the unit will display the pump's load value for 5 seconds, take
note of this value. When the LCD screen displays RUN=>xxx it indicates the minimum
load required to allow solar to run, set this value 15% lower than displayed LOAD value.
Note – SET MAN is usually the best option when setting the pump load settings for a
variable speed pump as the load value can fluctuate more.
AQUASMART 5 SV v1.4
MINUTE(S)
or
buttons to
8