Door Controls DC One Посібник з монтажу - Сторінка 10

Переглянути онлайн або завантажити pdf Посібник з монтажу для Система відкривання дверей Door Controls DC One. Door Controls DC One 20 сторінок. Automatic sliding door retrofit drive assembly

Trip Counter Reset
RESET TRIP COUNTER
Resets the trip counter
Resettable in program mode only
Faults Detected
FAULTS DETECTED
NONE
Lists the fault that the control is currently under
o
o
o
o
Learn Torque
LEARN TORQUE
020.5%
Ranges from 5 to 100%
Adjustable in or out of program mode
Learn Open Speed
LEARN OPEN SPEED
014.8%
Ranges from 5 to 100%
Adjustable in or out of program mode
Learn Close Speed
LEARN CLOSE SPEED
014.8%
Ranges from 5 to 100%
Adjustable in or out of program mode
Motor Type
SELECT MOTOR TYPE
DC ONE V3
Adjustable in program mode only
Phone Number
DOOR CONTROLS
800-437-3667
Software Version
DC ONE V3
FIRMWARE V 1.15
DC One V3 Installation Manual
M-0015 REV 06222017 P10
None
Broken or Loose Belt
Jammed Door
Obstruction Lockout
Control will remain in hold open after 3 consecutive obstruction errors
Control must be reset or turned off to clear error
Off is preferable to prevent a relearn cycle after a reset