J6 – Safety Beams – Pins 7 to 10
•
•
•
J5 – Inner and Outer Sensors
•
•
•
•
J7 – Special Modes
•
•
•
•
•
J8 – Lock
•
•
•
12. HOW TO ENTER PROGRAM MODE
Press both the RESET and the PROGRAM button.
Release the RESET button and continue to hold the PROGRAM button
After the display changes, release the PROGRAM button
You are now in program mode.
After making changes, press RESET to exit program mode
The control will perform a learn cycle on the first activation after a reset
DC One V3 Installation Manual
M-0015 REV 06222017 P10
Activates the door except when in the closed position
24 VAC power to safety beam module
Red LED is on when active
Separate 24 VAC connections for sensor power
Inner Sensor
Activates door except when off or in night mode
o
Green LED is on when active
o
Outer Sensor
Activates door except in off, one way, or night mode
o
Green LED is on when active
o
Safety
Activates the door except when in the closed position
o
Red LED is on when active
o
Emergency Open
Activates the door during all modes
o
Green LED is on when active
o
Ratchet
Activates door and stays open until ratchet is pressed again
o
Does not activate during off, one way, or night mode
o
Green LED is on when active
o
Activation
Activates the door during all modes
o
Green LED is on when active
o
Breakout
Stops door motion
o
Software selectable polarity (NO/NC)
o
Red LED is on when active
o
Night Mode
Disables inner and outer sensors in closed position
o
Door activates with emergency open and activation input only (pin 2 or 6 of J7)
o
Yellow LED is on when active
o
Pins 1 to 6 are used to control the DC One lock
Lock voltage is selectable between 12 and 24 volts with toggle switch