DoorHan PCB-SW Інструкція з програмування - Сторінка 16
Переглянути онлайн або завантажити pdf Інструкція з програмування для Система відкривання дверей DoorHan PCB-SW. DoorHan PCB-SW 20 сторінок. Control board
Також для DoorHan PCB-SW: Інструкція з програмування (20 сторінок)
2.4. ADVANCED PROGRAMMING
To perform advanced programming do the following:
1. Press and hold the «P» button for 10 seconds to enter the advanced programming. The left part of the display will show
«0», and the right part will show the menu item (see the Advanced Programming table).
2. Pressing the «+» or «-» buttons select the required menu item.
3. Press «P» to enter the menu item, the value of the adjusted parameter will start flashing on the display.
4. Pressing the «+» or «-» buttons change the value of the selected item.
5. Press «P» to save new value and exit to the main menu.
6. Having adjusted all the required parameters press «R» to exit the programming menu.
NOTE:
If you need to exit to the main menu without saving the parameters press «R».
Menu item Function
Pass door or single-leaf gate automation mode:
0.0
Y — enabled; n — disabled
Force on the 1st leaf:
0.1
1 — minimum force; 6 — maximum force
Force on the 2nd leaf:
0.2
1 — minimum force; 6 — maximum force
Maximum force at the start:
0.3
Y — enabled; n — disabled
Pre-activation of signal lamp(5 sec):
0.4
Y — enabled; n — disabled
Operation logics of the electric lock terminals (19-21):
0.5
Y — элетромагнитный; n — электромеханический
Closing safety devices activation:
0.6
Y — reverse movement after the gate opening is freed of obstruction; n — immediate reverse movement
Automatic gate closing after activation of photocells:
0.7
Y — enabled; n — disabled
Gate opening/closing with buttons held pressed (faulty remote control):
0.8
Y — enabled; n — disabled
Prohibition of the control commands acceptance during gate opening:
0.9
Y — enabled; n — disabled
Separate control logics:
S-B-S button — gate opening and stopping;
1.0
PED button — gate closing and stopping;
Y — enabled; n — disabled
1st leaf opening time with PED button:
1.1
0 — disabled; 1 — 3 sec; 2 — 4 sec; 3 — 5 sec; 4 — 8 sec; 5 — 15 sec; 6 — 20 sec; 7 — 25 sec; 8 — 30 sec; 9 — 40 sec
Remote programming:
1.2
Y — enabled; n — disabled
9.8
Reset to factory settings
9.9
Software version
2.5. RESET TO FACTORY SETTINGS
To reset the control board parameters to factory settings enter the advanced programming menu and select «9.8» item, press
the «P» button. The display will show «rE», press and hold the «P» button for five seconds. «rE» will stop flashing and the board
will be reloaded; short audio signal will be given. After this operation, all settings will be default.
NOTE:
When resetting to factory settings, the receiver memory is not cleared.
16
OPERATOR PROGRAMMING
Default
n
3
3
n
n
n
n
n
n
n
n
0
Y
rE