Baumer IO-Link RR30 Інструкція з експлуатації - Сторінка 12

Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Аксесуари Baumer IO-Link RR30. Baumer IO-Link RR30 40 сторінок. Radar sensor

Baumer IO-Link RR30 Інструкція з експлуатації

4.3 Switching Signal Channel (SSC)

The sensor features three different switching channels. Switching Signal Channels SSC1 and SSC2 are
reserved for distance measurements, whereas Switching Channel 4 has a counter function with an auto-
reset. All switching channels can be adjusted via IO-Link. All switching channels can be mapped to the MDC
as well.
For more information about how to set-up the Counter/SSC4 channel and its behavior, please see section 0.

Setpoint SP

4.3.1
Using this parameter the user can modify the switching point of the sensor by entering the distance value at
which the sensor should switch (teach-by-value function), change the value For Single point mode only SP1
is relevant, SP2 is not active. For the Window mode SP1 & SP2 are active. The switching modes are
explained in section 4.3.4
Figure 6 Single Point Mode
SP1: Switch point 1
SP2: is not active
Parameter name
SSC1 Param.SP 1
SSC1 Param.SP 2
en_BA_RR30_IO-Link_V0.23.docx
13.01.2021/
Short Description
Set the distance at which the related
SSC is set to active (or inactive if
inverted)
Set the distance at which the related
SSC is set to inactive (or active if
inverted). Only active if SSC is set to
window mode
Figure 7 Window Mode
SP1: Switch point 1
SP2: Switch point 2
Rights
rw
rw
12/40
Unit / Allowed values
Limits:
- 200 - 8000 mm;
- 300 - 15000 mm;
- 400 - 80000 mm;
Default: 1000 mm
Limits:
- 200 - 8000 mm;
- 300 - 15000 mm;
- 400 - 80000 mm;
Default:
2000 mm; 5000 mm;
20000 mm
Baumer Electric AG
Frauenfeld, Switzerland