4.3.8.2 SSC4 Behavior
By enabling auto reset, a full-featured counter being able to count lot sizes can be created without any need
of a manual reset.
Time filters like Response Delay can help to optimize the timing of the execution of a subsequent actor.
Figure 22 illustrates the behavior of SSC4 using different setting. SSC4 source is hereby the switch counter
of SSC1.
Figure 22: Behavior SSC4/Counter: Single-Point or Window, Auto reset enabled or disabled
auto
4.4 Teach Channel Selection & Teach Status
The described teach commands can be applied to individual switching signal channels. Before proceeding
with the teach-in procedure, make sure to select the SSC that should be addressed.
Furthermore different information are available to indicate the current mode and teach-in state of the
selected switching signal channel to help to execute the right commands described in section Fehler!
Verweisquelle konnte nicht gefunden werden. and Fehler! Verweisquelle konnte nicht gefunden
werden..
Parameter name
TI Select
TI Info.Mode of TI Select
TI Result.State
en_BA_RR30_IO-Link_V0.23.docx
13.01.2021/
Pulse: only negative pulses are
prolonged
Short Description
Selection of the SSC for which
the teach commands are valid
(TI Select - Teach-In Select)
Mode of the selected Teach
channel
Shows the teach status of the
teach-in process
20/40
Rights
Unit / Allowed values
rw
- Default (SSC1) / SSC1 /
SSC2
- Default: Default
Single Point / Window
ro
ro
- 0 = Idle
- 1 = SP1 Success
- 2 = SP2 Success
Frauenfeld, Switzerland
Baumer Electric AG