Teaching the zero position
Instruction:
a) Press the teach button briefly.
ü
Green and yellow LEDs light up (teach button is active). If the LEDs do not light up, start
the sensor again.
b) Keep the teach button pressed for 2 seconds.
ü
Green LED blinks with 2 Hz.
c) Place the measurement object on the desired position for the zero point and briefly press
the teach button within 60 seconds.
Result:
ü
Teach-in OK: Green and yellow LEDs light up briefly. Afterwards, the sensor goes back to
operating mode.
ü
Teach-in not OK: Green and yellow LEDs blink simultaneously with 8 Hz.
After the zero point is shifted,
the digital measured values before the zero point (in the direction of the sensor) are output
n
as negative and those after the zero point are output as positive measured values.
the limits of the analog measurement field have shifted. Therefore, parameterize the analog
n
measurement field again.
Resetting to the factory settings
Instruction:
a) Press the teach button briefly.
ü
Green and yellow LEDs light up (teach button is active). If the LEDs do not light up, start
the sensor again.
b) Keep the teach button pressed for 8 seconds.
ü
Yellow and green LEDs blink simultaneously with 2 Hz.
Result:
ü
Teach-in OK: Green and yellow LEDs light up briefly. Afterwards, the sensor goes back to
operating mode.
ü
Teach-in not OK: Yellow and green LEDs blink simultaneously with 8 Hz.
OM20/OM30 | V1
Sdc
ZP
P1
-
+
measurement field
Sde
P2
Analog
Operating Manual
Description
|
3