Baumer OM30 Посібник з експлуатації - Сторінка 36

Переглянути онлайн або завантажити pdf Посібник з експлуатації для Аксесуари Baumer OM30. Baumer OM30 48 сторінок. Laser distance sensors

Baumer OM30 Посібник з експлуатації
8
|
Functions
8.11

Function of the Teach button

With the Teach button function (Local User Interface), you have the option of specifying the
mode of the Teach button. You have a choice between the Xpert (factory setting) and Xpress
modes. The mode is selected via the IO-Link.
Adjustable parameters in the Xpert mode:
Analog measurement field
n
Zero position
n
Resetting the sensor to the factory settings
n
For more information on the operation of the Teach button in the Xpert mode, see
[} 11].
Adjustable parameters in the Xpress mode:
Zero position
n
The Teach button is automatically deactivated after 5 min (the timeout can be parameterized via
IO-Link).
Teaching the zero position (in the Xpress mode)
Instruction:
a) Place the measurement object at the desired position for the zero position.
b) Keep the Teach button pressed for 2 seconds.
ü
Green LED blinks with 2 Hz.
Result:
ü
Teach-In ok: Sensor goes back to the operating mode.
ü
Teach-in not OK: Green and yellow LEDs blink simultaneously with 8 Hz.
IO-Link parameter: Teach button (Local User Interface)
Parameter name
Teach Mode Settings.Local Teach
Mode
Teach Lock Settings.Button Time Out -
36
Values Description
Xpert,
Xpress
Operating Manual
Selecting the mode for the Teach button
Enter the time period (Timeout) after which the
Teach button should be deactivated after a
teach-in process (in min). With a value of 0, the
Teach button is always activated. With a value
of 255 (0xFF), the Teach button is perma-
nently deactivated.
Baumer
Teach button
OM20/OM30 | V1