Douglas Dynamics DD 99494 Посібник - Сторінка 5
Переглянути онлайн або завантажити pdf Посібник для Світильник Douglas Dynamics DD 99494. Douglas Dynamics DD 99494 6 сторінок. Strobe light kit stainless steel hopper spreaders
Electrical Connections
1. Plug the relay/fuse harness 10-pin connector into
the relay/fuse assembly.
2. Plug the strobe light harness connectors into the
matching connectors on the relay/fuse assembly
harness.
3. Remove the cover from the isolated stud block and
connect the relay/fuse assembly harness red wire
to the POSITIVE (+) terminal and the black wire
to the NEGATIVE (–) terminal. Replace the cover,
being careful not to pinch any wires. On spreader
Electric Spreader
Lit. No. 92945, Rev. 05
Gas Spreader
installations with multiple accessories, it may be
necessary to notch the sides of the isolated stud
block cover to accommodate all the wires.
4. Electric Spreaders: Connect the single-pin
terminal on the relay/fuse assembly harness
(yellow wire) to the white wire coming from port A
of the spreader module.
Gas/Hydraulic Spreaders: Connect the
single-pin terminal on the relay/fuse assembly
harness (yellow wire) to the white wire coming
from the previously installed hopper accessory
cable assembly.
Isolated
Stud Block
Hydraulic Spreader
5
Electric Spreader (0.35 & 0.7 yd
99494
3
)
August 1, 2020