Dover PSG BLACKMER MRLN4B Інструкції з монтажу, експлуатації та технічного обслуговування - Сторінка 12
Переглянути онлайн або завантажити pdf Інструкції з монтажу, експлуатації та технічного обслуговування для Водяний насос Dover PSG BLACKMER MRLN4B. Dover PSG BLACKMER MRLN4B 20 сторінок. Power pumps
MAINTENANCE: PUMP MODEL: MLN4B, MRLN4B
Failure to disconnect and lockout
electrical power before attempting
maintenance can cause shock, burns or
death
Hazardous
machinery can
cause serious
personal injury.
Failure to stop the pump before
adjusting the shaft packing can cause
severe personal injury.
Hazardous
machinery can
cause serious
personal injury.
Failure to relieve system pressure prior
to performing pump service or
maintenance can cause personal injury
or property damage.
Hazardous pressure
can cause personal
injury or property
damage
Failure to disconnect and lockout
electrical power before attempting
maintenance can cause shock, burns or
death
Hazardous voltage.
Can shock, burn or
cause death.
Disconnecting fluid or pressure
containment components during pump
operation can cause serious personal
injury, death or major property damage
Hazardous pressure
can cause personal
injury or property
damage
If pumping hazardous or toxic fluids,
system must be flushed and
decontaminated, inside and out, prior to
performing service or maintenance
Hazardous or toxic
fluids can cause
serious injury.
NOTICE:
Maintenance shall be performed by qualified
technicians only, following the appropriate procedures
and warnings as presented in this manual.
SCHEDULED MAINTENANCE
STRAINERS
Strainers must be cleaned regularly to avoid pump starvation.
Schedule will depend upon the application and conditions.
LUBRICATION
To avoid possible entanglement in moving parts do not
lubricate gear reducer or any other parts while the pump is
running.
Sleeve bearings (bushings) are lubricated by the liquid being
pumped. Additional lubrication is not required.
IF EQUIPPED: Blackmer gear reducers are shipped from the
factory without oil in the gearcase. Fill with the grade of oil
indicated on the reducer tag. Change the oil after the first 48
hours of use and approximately every 500 hours of use
thereafter.
VANE REPLACEMENT
Maintenance shall be performed by qualified technicians
only. Following the appropriate procedures and warnings
as presented in manual.
1.
Remove the head assembly (20) and all other parts on the
outboard (non-driven) side of the pump. See the "Pump
Disassembly" Section.
2.
Turn the shaft by hand until a vane (14) comes to the top
(12 o'clock) position of the rotor.
3.
Remove and replace the vane, making sure to install the
vane with the rounded edge outward to contact the liner
(41).
4.
Rotate the shaft until the next rotor slot is in the top
position, and replace the vane.
5.
Continue this procedure until all new vanes are in place.
6.
Reassemble the pump per "Pump Assembly."
106-A00
Page 12/20
NOTICE:
NOTICE: