Dover HYDRO EvoWash Посібник із швидкого старту - Сторінка 5
Переглянути онлайн або завантажити pdf Посібник із швидкого старту для Диспенсер Dover HYDRO EvoWash. Dover HYDRO EvoWash 19 сторінок.
installation (continued)
Optional Rinse Pump Tubing Connections
NOTE! Cable ties are provided in the fittings kit so
that tubing can be tied together or to the wall, to
create a neat and safe installation.
Inlet Tubing
1) Using the ¼" tubing provided, cut the tube to the correct
length (keeping enough for the outlet tubing) and install
the strainer & weight onto the end of the tube that will be
placed into the rinse chemical container.
2) Install the strainer and weight into the rinse chemical
container, ensuring that any entry hole produced in the
container is suitable as not to allow particulates or any
contamination to enter the container.
3) Connect the inlet tubing to the inlet on the rinse pump
(left hand fitting). Loosen the compression fitting by 1
turn, then push the tube into the fitting and tighten.
Outlet Tubing
1) Install one end into the outlet of the rinse pump (right hand fitting). Loosen the compression fitting by 1 turn, then push the
tube into the fitting and tighten.
2) Before cutting, measure the tubing length needed to reach the location where you will be installing the rinse injection fitting,
and include some extra length for routing the tubing out of the way.
Optional Rinse Pump Injection Fitting
NOTE! Only applicable to models that have the
optional rinse pump fitted. You must install the
rinse injection fitting downstream of any rinse
solenoid.
CAUTION! Ensure there are no kinks or sharp
bends in the tubing between the pump and the
rinse injection fitting, to ensure free flow of rinse
chemical into the rinse water.
CAUTION! Choose a location for the rinse
injection fitting that allows the installation to comply
with local and national plumbing regulations,
ensuring there is no backflow of rinse chemicals
into a potable or municipal water supply.
Installation Method 1:
1) Most machines will have a 1/8" NPT inlet blanked off on the rinse water manifold.
2) Remove the blanking cover and install the rinse injection fitting. Use thread sealant to ensure a leak free assembly.
Installation Method 2:
1) Drill a 5.5mm (7/32") hole in the location at which you have decided to install the rinse pump injection fitting.
2) Cut threads into the hole using a 1/8" NPT tap, ensuring that all sharp edges, cutting debris and burrs are removed.
3) Install the rinse pump injection fitting. Use thread sealant to ensure a leak free assembly.
Connect pump discharge tubing:
1) Ensure the pump discharge tubing is long enough to reach the rinse injection fitting with enough extra to allow neat
and safe routing. Connect the end of the tubing to the rinse injection fitting going into the dish machine. Loosen the
compression fitting by 1 turn, then push the tube into the fitting and tighten.
NOTE: North America Model Shown
Rinse Pump Inlet
To Rinse
Product Container
To Rinse
Injection Fitting
Threads into Rinse
water plumbing
Rinse Pump Outlet
Compression
fitting (1/8" tube)
Rinse Feed
Outlet Hose
1/8" NPT
Male
5