To start up and operate dispenser ––––––––––––––––––––––––––––––––––––
1. Follow detailed cleaning instructions in service manual before operating dispenser.
2. For manual load units, remove front drain pan or rear lid and fi ll storage area with compatible ice.
Follett manual load dispensers can accommodate most cube/cubelet ices up to 26mm square and
!
Follett compressed nugget ice. Crushed, fl ake, nugget, bagged or congealed ice cannot be used. Use
of these ices can jam dispenser and void warranty. Separate any "waffle-like" sections of cubes before
adding to dispenser. For questions about ice compatibility, call Follett's customer service group at (610)
252-7301.
3. Turn power switch located on control box to "ON" position.
4. For automatic fi ll units, follow detailed instructions in ice machine installation section of installation manual, then
turn ice machine (bin signal) switch(es) located on control box to "ON" position and begin to make ice.
5. When dispenser has at least 153mm of ice in storage area, press "PUSH FOR ICE" lever or button to ensure
that dispenser is operating properly. Note: If additional start-up information is needed, call Follett Corporation at
+1 (610) 252-7301.
User information –––––––––––––––––––––––––––––––––––––––––––––––––––
How the dispenser works
Follett's EU155N Series ice and water dispensers are available in manual load confi gurations (using ice from
another source) or automatic load confi gurations, fed from one or two Follett 400 lb (181kg)/day remote ice
machines.
In all models, ice is stored below the counter in the dispenser storage area. When the dispense lever or button is
pushed, the dispense motor is activated. This causes the wheel assembly in the storage area to turn, moving ice to
the vertical auger assembly, which carries ice up to the dispense chute where it drops by gravity into the container.
In automatic load units, ice is manufactured in either one or two Follett remote ice machines. These ice machines
may be located up to 6m away from the dispenser. As water freezes to the inside walls of the ice machine
evaporator, a rotating stainless steel auger removes ice and carries it to the top of the evaporator assembly where it
is compressed and extruded through an outlet port. The extruded ice is then pushed through the tube to the storage
compartment of the dispenser. A level fi ll circuit maximizes fi ll in the storage area by rotating the wheel at intervals
until the bin is completely fi lled. When the bin is fi lled, a bin stat shuts the ice machine off to avoid overfi lling of the
bin. The ice machine will restart after 20 minutes if the bin is calling for ice.
Cleaning and sanitizing procedures –––––––––––––––––––––––––––––––––––
Warning!
!
Always disconnect power before cleaning dispenser.
Using solutions below, clean and sanitize storage area and beverage lines before starting up unit and on a routine
basis as noted below.
Solution A:
Prepare a cleaning solution (200 ppm of available chlorine content) of chlorinated detergent. Cleaning
solution temperature must be at 75˚ – 125˚F (24˚ to 52˚C).
Solution B:
Prepare a sanitizing solution (50 ppm of available chlorine content) of chlorinated detergent.
Sanitizing solution temperature must be at 75˚ – 125˚F (24˚ to 52˚C).
EU155N Ice and Water Dispensers