The HyperBlast charger can be used in either 110 volt 60 hz countries, or in 220
Volt 50 Hz countries. It is very important to set the 110/220 switch on the rear of the
unit to the correct voltage. Failure to set this correctly will destroy the charger. If your
charger does not have this 110/220 switch, then it will autodetect the correct voltage.
Status LED
On Solid
Slow Blink – Once per second
Fast Blink – 5 times per second
All LEDs blinking rapidly in sequence
Battery Status
Battery is Rapid Charging
Battery has peaked and is now trickle
charging at 3% of capacity
Battery Charger has shut off because one
of the following:
a) The battery is full
b) The battery is > 50 Deg C
c) The charge time has expired
The Charger has detected an internal
charger temperature greater than 70 Deg
C. and has shut down all outputs. You
must turn the power off and back on in
order to reset the charger.
110/220
Voltage