Ovens Platform Customer Support
Technical Training & Service
4. Offset calibration of cavity probe
In order to adjust the offset of the cavity probe, enter in parameter programming and set parameter cort to
0.
Then run a steam cycle for several minutes and check the cavity temperature, which should stabilize at the
water boiling point (according to the altitude above sea level). If the stabilized cavity temperature is less or
greater than the correct water boiling point
After this, set parameter cort to 1and set parameter SEAL (altitude above sea level).
5. Alarm codes
Alarms can be divided into 2 categories: errors (they stop the appliance) and warnings (they do not stop
the appliance)
If one or more errors occurs the service icon becomes red
in maintenance page. The list of alarms is displayed (Fig.16).
5.1.
Errors
Epxx: If the controller detects one or more parameters which have values not permitting the minimum
operational requirements, an error code will appear on the display, i.e. "Epxx" followed by the parameter
number. Enter the programming mode and set the correct value according to the parameter list.
EtUC: Cavity over temperature; cavity temperature exceeded value stored in parameter cot.
EtUB:
Boiler over temperature; boiler temperature exceeded value stored in parameter bot.
EFup/Efdw: Activation of the thermal protection of up or down motor. The thermal protection has an
automatic reset but in order to continue with the cooking process, parameter ALFn has to be reset to 0 to
restart the oven.
Etc: Tripping out of cavity limiter
Etb: Tripping out of boiler limiter
Esch: Over temperature on the electronic board; check the cooling fan and the ventilation openings on the
bottom of the control panel.
Ecel: cavity probe in open circuit (only the steam cycle – 100 °C can be selected)
Ebol: boiler probe in open circuit (only hot air cycle can be selected)
Eprb: meat probe in open circuit (only time cooking can be selected)
Ebyp: by-pass probe in open circuit (only hot air, regeneration or low temperature steam cycle can be
selected)
Entc: NTC probe in short or open circuit
ECAD: A/D converters not working
1
See Appendix A
File: AOSpeed service manual (ENG).001
AOSpeed OVENS
(593800300 - ENG)
1
, a corrective value can be stored in parameter OCA1.
Fig.16
©Copyright 2002 by Electrolux Professional
Service Manual
. By pressing the button P4 you enter
P.7/20