E MW: magnetron alarm. Only the generation o the microwave will be stopped. The oven can cook in the
traditional way. Enter in programming mode and check the value of parameter ALmg. See parameter list to
understand which magnetron/s was/were faulty. Set to 0 the parameter ALmg.
E SL: boiler water level probes always in closed circuit. They continuously detect the presence of water.
Parameter ALFn has to be reset to 0 to restart the oven.
ECLO: clock error. It appears if the clock was never adjusted.
E PWM: Communication error with PWM system
Ecup: Reset of cavity burner (gas oven) (the upper one in the 20 grid ovens)
Ecdw: Reset of lower cavity burner (gas oven) in 20 1/1 and 2/1 ovens
Ebup: Reset of boiler burner (gas oven) (the upper one in 20 2/1 ovens)
Ebdw: Reset of lower boiler burner (gas oven)
Ertc: A component of the PCB is not dialoguing (Real time clock problem)
Eram: problems to read the RAM
Epar: parameter alarm on the EEPROM. Impossibility to read/write parameters
Epix: problem on the program index of the Factory recipes in the EEPROM
Epha: problem on the program phase of the Factory recipes in the EEPROM
Edes: problem on the description of the factory recipes in the EEPROM
Efau: problem on the automatic recipes in the EEPROM
Efrz: problem on the frozen food index in the EEPROM
Ecat: problem on the category index of food in the EEPROM
5.2.
Warnings
EH2O: Before the starting of the cleaning system and during its working, there are some check points of
the water pressure. If the water pressure is too low this warning message appear on the display. Check
the water pressure (1.5÷2.5 bar), check the correct working of the water pressure switch, check if there are
obstructions on the cleaning water inlet pipe (its inner diameter must be 20 mm). From firmware release
2.50, EH2O is a warning message and no more an error causing the stopping of the cleaning cycle.
EFLP: Cavity ventilation flap failure; check the motoreducer or the micro switch that detects the close
position of the flap. If the motoreducer does not close the flap within the time set in parameter FLto, EFLP
error appears.
EPrG: Error in reading the phases of a multiphase recipe
The following warnings are showed by an icon on the top right side of the screen:
Safety level probe of the boiler out of water
Preheating phase of the boiler
Boiler to be descaled
Door open
File: AOSpeed service manual (ENG).001
AOSpeed OVENS
(593800300 - ENG)
©Copyright 2002 by Electrolux Professional
Service Manual
P.8/20