Anderson Thermal Solutions – FFA12 Burner Operation Manual
pipe or gas pipe connected with burner should be tight enough with no leakage, also
the periodically check air or fuel nozzles of the burners to prevent to be blocked by
dust, slag or other materials.
ATTENTION:DANGER OF BEEN BURNT
When burner in operation, combustion is severe, so the burner must be fixed. Hoses
or cables in area of the combustion system must be suitable for high temperature, to
prevent high temperature failure or cause safety accidents. Burners should be
periodically inspected and cleaned. Copper wire brush may be used, if necessary, to
clean burner head. The burner system should be checked twice a year for safety
operation.
4. Description
FFA12 – FlexFire® Air burner is trademark of Anderson Thermal Solutions (Suzhou) Co.,
Ltd., it is designed for regenerative glass furnace, with adjustable mechanism for flame
length and energy release position.
FFA12 fuel burner has an adjustable fuel burner designed for sealed combustion and
can use standards-compliant liquid fuels with a viscosity of 100 SSU or less, long service
life, work with heat and dirty air, and low maintenance.
It is widely used for the installation of side-fired and bottom-fired end port and cross
fire furnaces
Figure 1: Flex Fire®-Air Oil Brenner
Anderson Thermal Soluions(Suzhou)Co., Ltd
3