7 Troubleshooting

WARNING
The appliance shall be stored in a room without
continuously operating ignition sources (example: open
flames, an operating gas appliance or an operating electric
heater).
WARNING
▪ Do NOT pierce or burn refrigerant cycle parts.
▪ Do NOT use cleaning materials or means to accelerate
the defrosting process other than those recommended
by the manufacturer.
▪ Be aware that the refrigerant inside the system is
odourless.
WARNING
▪ The refrigerant inside the unit is mildly flammable, but
normally does NOT leak. If the refrigerant leaks in the
room and comes in contact with fire from a burner, a
heater, or a cooker, this may result in fire, or the
formation of a harmful gas.
▪ Turn OFF any combustible heating devices, ventilate
the room, and contact the dealer where you purchased
the unit.
▪ Do NOT use the unit until a service person confirms
that the part from which the refrigerant leaked has been
repaired.
6.2
To find the contact/helpdesk
number
Prerequisite: You switched the permission level to Advanced end
user.
1 Go to [6.3.2]:
> Information > Error
Contact/helpdesk number.
7
Troubleshooting
If a malfunction occurs,
is displayed on the home pages. You can
press
to display more information about the malfunction.
For the symptoms listed below, you can try to solve the problem
yourself. For any other problem, contact your installer. You can find
the contact/helpdesk number via the user interface.
7.1

To check the error history

Prerequisite: Only available if
1 Go to [6.3.1]:
> Information > Error handling > Error
history.
Operation manual
10
handling >
is displayed on the home pages.
7.2
Symptom: You are feeling too cold
(hot) in your living room
Possible cause
The desired room temperature is
too low (high).
The desired room temperature
cannot be reached.
The weather-dependent curve is
set incorrectly.
7.3
Symptom: The water at the tap is
too cold
Possible cause
You ran out of domestic hot
water because of unusually high
consumption.
The desired DHW tank
temperature is too low.
Corrective action
Increase (decrease) the desired
room temperature. See
"4.3.2 Room thermostat control -
Using the room temperature
pages" [ 4  7].
home
If the problem recurs daily, do
one of the following:
▪ Increase (decrease) the room
temperature preset value. See
the user reference guide.
▪ Adjust the room temperature
schedule. See
"4.5 Schedules:
Example" [ 4  9].
Increase the desired leaving
water temperature in accordance
with the heat emitter type. See
"4.3.3 Room thermostat control -
Using the leaving water
pages" [ 4  8].
temperature home
Adjust the weather-dependent
curve. See the user reference
guide.
Corrective action
If you immediately need domestic
hot water, activate the DHW tank
booster mode. However, this
consumes extra energy. See
"4.4.5 Using the DHW tank
mode" [ 4  8].
booster
If you can wait, overrule
(increase) the active or next
scheduled desired temperature
so that more hot water will be
produced exceptionally. See
"To
read out and overrule the active
or next scheduled desired
temperature (in scheduled mode
or scheduled + reheat
mode)" [ 4  8].
If the problem recurs daily, do
one of the following:
▪ Increase
the
DHW 
tank
temperature preset value. See
the user reference guide.
▪ Adjust
the
DHW 
tank
temperature
schedule.
Example:
Program
to
additionally
heat
up
the
DHW  tank to a preset value
(Storage
eco = lower tank
temperature) during the day.
See
"4.5 
Schedules:
Example" [ 4  9].
EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596819-1B – 2021.10