7.4
Symptom: Heat pump failure
When the heat pump fails to operate, the backup heater can serve
as an emergency heater and either automatically or non-
automatically take over the heat load.
▪ When auto emergency is activated and a heat pump failure
occurs, the backup heater will automatically take over the heat
load.
▪ When auto emergency is not activated and a heat pump failure
occurs, the domestic hot water and space heating operations will
stop and need to be recovered manually. The user interface will
then ask you to confirm whether the backup heater can take over
the heat load or not.
When the heat pump fails,
will appear on the user interface.
Possible cause
Heat pump is damaged.
INFORMATION
When the backup heater takes over the heat load,
electricity consumption will be considerably higher.
7.5
Symptom: The system is making
gurgling noises after
commissioning
Possible cause
There is air in the system.
Incorrect hydraulic balance.
Various malfunctions.
(a)
We recommend to purge air with the air purge function of the unit
(to be performed by the installer). If you purge air from the heat
emitters or collectors, mind the following:
WARNING
Air purging heat emitters or collectors. Before you
purge air from heat emitters or collectors, check if an error
or
is displayed on the home pages of the user interface.
▪ If not, you can purge air immediately.
▪ If yes, make sure that the room where you want to
purge air is sufficiently ventilated. Reason: Refrigerant
might leak into the water circuit, and subsequently into
the room when you purge air from the heat emitters or
collectors.
EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596819-1B – 2021.10
Corrective action
▪ Press
to view a description
of the problem.
▪ Press
again.
▪ Select
to allow the backup
heater to take over the heat
load.
▪ Call your local dealer to get
the heat pump fixed.
Corrective action
(a)
Purge air from the system.
To be performed by the installer:
1
Perform hydraulic balancing
to assure that the flow is
correctly
distributed
between the emitters.
2
If hydraulic balancing is not
sufficient, change the pump
limitation
settings
([9-0D]
and [9-0E] if applicable).
Check if
is displayed on the
home pages of the user
interface. You can press
to
display more information about
the malfunction.
8
Disposal
NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation. Units
MUST be treated at a specialised treatment facility for
reuse, recycling and recovery.
9
Glossary
DHW = Domestic hot water
Hot water used, in any type of building, for domestic
purposes.
LWT = Leaving water temperature
Water temperature at the water outlet of the unit.
10
Installer settings: Tables to be
filled in by installer
10.1
Quick wizard
Setting
Forced off contact [A.2.1.6]
Forced off contact
Space heating settings [A.2.1]
Unit control method
User interface location
Number of LWT zones
Pump operation mode
Domestic hot water settings [A.2.2]
DHW operation
DHW tank type
DHW pump
Thermostats [A.2.2]
Contact type main
Contact type add.
External sensor
Digital I/O PCB [A.2.2.6]
Ext. backup heat src
Alarm output
Bottom plate heater
Demand PCB [A.2.2.7]
Demand PCB
Energy metering [A.2.2]
External kWh meter 1
External kWh meter 2
Capacities (energy metering) [A.2.3]
BUH: step 1
10.2
Space heating/cooling control
Setting