Atlas MVXA Посібник користувача - Сторінка 7
Переглянути онлайн або завантажити pdf Посібник користувача для Підсилювач Atlas MVXA. Atlas MVXA 8 сторінок. Multi-channel amplified monitor panel
MVXA SERIES
MULTI-AMPLIFIED MONITOR PANEL
MVXA Series Back Panel View (Rear Panel Cover Removed)
15. Terminal Inputs
Each of the unit's eight or sixteen channel inputs is
independent allowing audio and visual monitoring of
any combination of 25V, 70V, and 100V, and line
level circuits. Each channel provides level indication
and is selectable to a "0" dB reference through easily
accessible jumpers. The available references are
shown in Table 1.
Since each channel is independent, the MVXA can
monitor multiple signal types. For example: Ch1
could be a line level, Ch2 the 70V output from an
amplifier, Ch3 a line level from another source, etc.
The default setting for all channels is 70V.
Table 1: Choose jumper settings to match desired 0dB reference (25, 70V, 100V, or line level).
Set Each Channel's
0dB Reference Level
1 2
Jumper Setting
Reference Voltage
Power Ref. into 8Ω
Power Ref. into 4Ω
156 Watts
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. •
©2006 ATLAS SOUND LP
3 4
25V
70V (Default Setting)
1 & 2
3 & 4
25Vrms
70 Vrms
78 Watts
613 Watts
1225 Watts
Specifications are subject to change without notice
AtlasSound.com
Printed in China
16
16. Jumpers
Jumpers are to be adjusted prior to applying power
to the MVXA monitor panel. Jumpers have an
extended tab for ease of placement.
Always put the jumpers on the same numbers. Ex: 1
& 2, 3 & 4, or 4 & 5. No jumpers are used for the 100
Volt input setting.
17. Rear Panel Cover (Not Shown)
The protective rear panel cover should be placed on
the unit after wiring to avoid accidental contact with
rear terminals. The cover has knockouts on each end
to help with wire management.
N o n e
4 5
100V
Line Level
None
4 & 5
100Vrms
1Vrms
1250 Watts
0.13 Watts
2500 Watts
0.25 Watts
TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
00606
OWNER'S MANUAL
15
WARNING!
Place jumpers
lengthwise only
as shown in these
diagrams!
Jumpers must be
adjusted before
applying power!
AT000384 RevB 06/06
PN 484004
7