Advanced Radio Air Safe Посібник користувача - Сторінка 6

Переглянути онлайн або завантажити pdf Посібник користувача для Обладнання для запису Advanced Radio Air Safe. Advanced Radio Air Safe 12 сторінок. Failsafe gear sequencer

Fail Safe Screen

This screen shows you the (LV) Live or absolute system
pressure as well as the selected (FS) Fail Safe pressure.
To set the Fail Safe pressure (the pressure at which the
gear will be triggered to the down position) you:
1)
Pump up the system pressure to the desired Fail
Safe pressure.
2)
Move the cursor to the "SET FAIL SAFE" menu
item and press the joystick once.
The "SET FAIL SAFE' menu item will flash several times
and the current system pressure will be captured as the
fails safe trigger pressure. The FS 0.0 PSI will take on
the value of the system pressure and the "SET FAIL
SAFE" menu item will change to read "CLEAR FAIL
SAFE". From this point forward if the system pressure
drops below the Fail Safe pressure a gear down event will be triggered.
You can clear the Fail Safe pressure highlighting "CLEAR FAIL SAFE" and pressing the joystick.
Please Note: system pressures lower than the Fail Safe pressure will not allow
you to run the sequencer to the up position or allow system testing during set-
up so it is advisable to set the Fail Safe pressure after you have completed pro-
gramming the sequencer. You can clear the Fail Safe pressure trigger point at
any time by pressing "CLEAR FAIL SAFE"
Screens and Usage
RETURN
FS
0.0
LV
70.0
SET FAIL SAFE
RETURN
FS
70.0
LV
70.0
CLEAR FAIL SAFE
PSI
PSI
PSI
PSI
6