Absen CR0.9 Посібник користувача - Сторінка 18
Переглянути онлайн або завантажити pdf Посібник користувача для Монітор Absen CR0.9. Absen CR0.9 19 сторінок.
5. Maintenance
5.1 Preparation Tools
Preparation tools: Multi-meter, Module front service tools, Screwdriver, etc.
5.2 Rear Maintenance
Remove the back cover and HUB board from the back side of the cabinet to access the PCB board as the
modules can be accessed from the front. All the power supply, receiving card, and the HUB board can be
serviced by removing back cover.
Back cover
Power box
5.3 Test for short circuit
After finishing cabling the cabinets, use a multi-meter to test the AC input (L/N/PE) and DC output (VCC/GND) to
determine whether there is a short circuit. If a short circuit has been found, please examine the circuit carefully.
Power up the cabinets only after making sure all the circuits are working properly.
- 17 -
Panel
Receiving card
HUB board
Adapter plate
Leading
LED
Applications
Leading
LED
Applications
Light board
CR SeriesUserManual