settings are completed.
4.5.3 Setting description of user defined program:
Each program divides operating time into 16 time section. During setting, complete settings of
speed, lifting time and operating time of 16 time sections so that start key can be pressed to start
the treadmill.
4.6 Body fat measurement:
Press the "program switching" key continuously to enter the body mass index (FAT) detection
function in the standby state , and press the "target setting" key to enter the F-1, F-2, F-3, F-4, F-5
interfaces (f-1-gender, f-2-age, f-3-height, f-4-weight, F-5- body mass detection), Press the "Slope
︽" , "Slope︾" , "Speed+," Speed-"keys to set the parameters of 01-04 (the parameters are shown
in the following table). After setting, press the" Target Setting "key to enter the F-5 physical
examination interface. At this time, your body mass index will be displayed after holding the heart
rate handle in both hands for 5-6 seconds to see if your weight and height are commensurate. Body
mass index (FAT) is a measure of the relationship between a person's height and weight, not the
proportion of the body. FAT is suitable for any male or female and provides the basis for people to
adjust their weight together with other health indicators. The ideal FAT should be between 20 and 24.
If it is lower than 19, it means too thin. If it is between 25 and 29, it is overweight. If it is over 30, it is
considered obese. (This data is for reference only and cannot be used as medical data.)
4.7 Display range of each value:
Setting parameter
Time (m:s)
Slope (section)
Speed (km/h)
Distance (km)
Heart rate (time/m)
Calorie (kcl)
5.Safety lock function:
Pulling off the safety lock can stop the running of the treadmill in any state . The treadmill is
stopped in an emergency. The speed window displays "-",and the buzzer gives an alarm of "BB" 3
times. At this time, the treadmill cannot perform any other operation except shutdown. After the safety
lock is correctly installed again, the treadmill enters the standby state again, waiting for the input
command.
F-1
Gender
F-2
Age
F-3
Body height
F-4
Body weight
Body fat index
Body fat index
F-5
Body fat index
Body fat index
Initial
0:00
0
1.0
0.00
P
0.0
01Male
≤19
=(20---24)
=(25---29)
≥30
Setting initial value
30:00:00
0
1.0
1.00
N/A
50.0
-12-
02Female
10------99
100----200
20-----150
Too thin
Ideal
Overweight
Fat
Setting range
Display range
5:00-99:00
0:00-99:59
0-15
1.0-18
1.0-18.0KMH
0.50-99.90
0.00-99.90
N/A
50-200
10.0-999.0
0.0-999.0
0-15