DSC PC5928 Посібник із швидкого старту - Сторінка 10
Переглянути онлайн або завантажити pdf Посібник із швидкого старту для Блок управління DSC PC5928. DSC PC5928 16 сторінок. Audio interface module
Також для DSC PC5928: Інструкція користувача (2 сторінок)
P
R
O
G
R
Local Alarm Follower ..................................... Section [30], Option [1]
5.6
Talk/Listen-In
The "Event Buffer follows Swinger Shutdown" option must be enabled in the
PC5010 if Talk/Listen-In is used.
The PC5928 Audio Interface module has built-in Talk/Listen-In capability which can be
activated by zone alarms, keypad activated Auxiliary and Panic alarms, openings/closings,
duress alarms, tamper alarms, or opening after alarm conditions.
In all cases, the PC5010 must be programmed to report the event with communi-
cations enabled. For example, if a reporting code for a zone is not programmed,
it will not initiate Talk/Listen-In session.
The "Event Buffer Follows Swinger Shutdown" option must be enabled in the PC5010 to
ensure proper Talk/Listen-In operation.
A zone alarm will activate the feature if the zone is assigned to a station (Zone Assignment)
and the zone is enabled for Talk/Listen-In (Audio Control options). This is programmable by
zone. If the zone is not enabled in the Audio Control options, the zone will not initiate Talk/
Listen-In. If the zone is not assigned to a station, the PC5928 will turn on all stations.
All zones programmed as silent will not initiate a Talk/Listen-In session. Only a
Listen-In session can occur.
Keypad Panic alarms will activate the Listen In feature, if the Panic Keys Alarm option is
enabled.
Keypad Auxiliary alarms will activate the feature if the Auxiliary Keys Alarm option is enabled.
Listen in will be initiated if a Duress code is entered at a keypad and the Duress Alarm
option is enabled.
Talk/Listen-In will be initiated when the panel transmits opening and closing signals if the
Openings & Closings option is enabled. If this option is enabled, it is recommended to
enable the Duress Alarm option.
Talk/Listen-In will be initiated when a zone tamper condition occurs if the Tampers Enabled
option is enabled.
Module tampers will not initiate a Talk/Listen-In session.
Talk/Listen-In will be initiated when a zone expander supervisory trouble condition occurs if
the Zone Expander Supervisory Trouble Alarm option is enabled.
Talk/Listen-In will be initiated when the panel is disarmed after an alarm condition (Opening
After Alarm) if the Opening After Alarm option is enabled.
If the Listen To All Stations option is enabled the PC5928 will turn on all stations instead of
just the one closest to the zone or keypad.
A Talk/Listen-In session cannot be initiated for a 2-wire smoke or F-key alarm.
A
M
D
E
S
10
firealarmresources.com
C
R
I
P
T
I
O
N
S