Abstract Data Event Boss ADE-33 Посібник користувача - Сторінка 11
Переглянути онлайн або завантажити pdf Посібник користувача для Блок управління Abstract Data Event Boss ADE-33. Abstract Data Event Boss ADE-33 16 сторінок. Rhythm and pattern creation and manipulation
9) Global Mode 3: Probability
MODE OVERVIEW
The Probability mode is a set of pseudo-random and percentage chance-based algorithms.
Whether or not an input Event appears at the Output – or in what form it appears – is decided on by
'chance'. For this mode – 'chance' is a percentage betwen 0% (definitely will not happen) and 100%
(definitely will happen) that is set by a CV value of between 0-5V.
FIRST PATCH
• This mode is designed to work with most Event and CV types.
• Start with some sort of mid-tempo clock or square-wave LFO and a slow, evolving CV source.
• For each selected Local Mode – as the CV value changes – the Output pattern should also change.
INPUT TYPES
IN: GATE A1 & A2
IN: GATE B/CV
CV OPTIONS
Local
Global
LOCAL MODE 1: Percentage Pass
CV
Operation
LOCAL MODE 2: Percentage Block
CV
Operation
LOCAL MODE 3: Gate Tie
CV
Operation
LOCAL MODE 4: Gate Tie/Pass
CV
Operation
LOCAL MODE 5: Flip-Flop (Coin Toss)
CV
Operation
LOCAL MODE 6: Flip-Flop (Inversion)
CV
Operation
© 2018 Abstract Data Ltd.
• Any Event type e.g. clock, gate, trigger, square-wave or PWM-type LFO.
• Any 0-5V CV type e.g. LFO, envelope generator or variable CV source.
• 0-5V CV at IN: GATE B/CV sets each mode's probability or percentage chance.
• High Event at IN: MODE SELECT/RESET holds the last recorded CV value
• Any new CV values at IN: GATE B/CV are ignored.
• 0-5V CV sets the probability percentage from 0-100%.
• The percentage chance that an input Event passes to the output.
• 0-5V CV sets the probability percentage from 0-100%.
• The percentage chance that an input Event is blocked.
• 0-5V CV sets the probability percentage from 0-100%.
• The percentage chance that an input Event will be tied to the next input Event.
• 0-5V CV sets the probability percentage from 0-100%.
• The percentage chance that an input Event will be tied to the next input Event.
• Only Events that have been 'tied' to other Events are passed to the output.
• 0-5V CV sets the probability percentage from 0-100%.
• Each input Event is read as a 'coin toss'.
• Whether the Event is 'tossed' or not is set by the CV probability percentage.
• An Event that is 'tossed' has a 50/50 chance it will 'land' High or Low.
• 0-5V CV sets the probability percentage from 0-100%.
• The percentage chance that an input Event will be inverted at the output.
Page 9 of 13
Version 1.0.1