Datapath VisionLC-HD Посібник користувача - Сторінка 9

Переглянути онлайн або завантажити pdf Посібник користувача для PCI карта Datapath VisionLC-HD. Datapath VisionLC-HD 15 сторінок. Dual and single channel live capture cards
Також для Datapath VisionLC-HD: Посібник (2 сторінок)

Datapath VisionLC-HD Посібник користувача

Firmware Upgrades

All cards in the VisionLC range allow firmware upgrades to be completed on site rather than returning the card to Datapath.
the J4 Link MUST BE FITTED on the card.
Whenever a firmware upgrade is performed,
To perform the upgrade, follow the step-by-step instructions provided by the upgrade application.
In the unlikely event that something goes wrong during the upgrade process (e.g. System power outage) it is possible to revert
J4
to the factory settings by powering down the system, temporarily removing the
link then powering up the system with the
J4
link removed. Once the system has rebooted, replace the
link (whilst the system is powered up) and restart the firmware
upgrade process.
It should be noted that the latest driver installation program includes an automatic firmware update, if required. Therefore,
prior to installing the application and driver, ensure that J4 link is fitted.
8