Dux Automatic Посібник з експлуатації - Сторінка 6

Переглянути онлайн або завантажити pdf Посібник з експлуатації для Фарборозпилювач Dux Automatic. Dux Automatic 17 сторінок.

Operation Guide

Fluid Control Knob

The fluid control knob is located at the rear of the
spray gun (See Figure 3). To increase the fluid
flow,
turn
the
counter-clockwise. Conversely, turn the fluid
control knob clockwise to reduce the fluid flow.
Once the desired settings have been achieved,
turn the fluid control locking ring clockwise to
lock the fluid control knob into place (See Figure
3).
NOTE: If the fluid control knob stops offering
resistance, maximum needle travel has been
reached. If the flow rate is insufficient, increase
the fluid tip and needle size.
Fluid Control
Knob
Figure 3

Fan Control Adjustment

The fan control adjustment is located on the side
of the spray gun near the air cap. This
adjustment controls the amount of air delivered
to the horns of the air cap for spray pattern
shaping (See Figure 4).
NOTE: Applying excessive air to the air cap will
result in a split pattern.
The DUX Automatic spray gun features two
methods of fan control adjustment:
For customer service call 888 DUX AREA (888 389 2732)
fluid
control
knob
!
Locking Ring
!
Automatic Fan Adjustment: Spray guns configured
for automatic fan adjustment have an additional
push-lock fitting for fan control. Air is externally
supplied to the air horns of the air cap to control the
size and shape of the spray pattern. The more air
pressure applied, the larger the fan pattern. When
the optimal results are achieved, record the input
pressure settings for simple future setups.
Manual Fan Adjustment: Spray guns configured for
manual fan adjustment have a fan control valve
with a locking ring (See Figure 4). Pattern shaping
air is obtained from the main air chamber of the
spray gun. With the fan control valve in the fully
closed position (i.e. no threads showing), a
minimum spray pattern size is achieved. Pattern
size increases as the adjustment knob is rotated
counter-clockwise, allowing more air to be directed
to the air horns. When the optimal results are
achieved, turn the locking ring clockwise to lock
valve in place.
Manual Fan Control
Figure 4
Operating the Automatic Spray Gun
1. Turn on the regulated triggering air at a
minimum of 35 psi input pressure.
2. Turn on the regulated fluid line.
3. Trigger spray gun and observe fluid flow.
4. Turn the fluid control knob counter-clockwise
until desired flow rate is achieved.
5. Turn on the regulated atomizing air at the
source of supply.
6. Adjust
the
atomizing
desired fluid atomization is achieved.
7. Adjust fluid flow as necessary to achieve
desired results.

AUTOMATIC

Locking Ring
air
pressure
until
Page 5