Aussie Pumps AB Scud 40 Інструкція з експлуатації - Сторінка 9
Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Мийка високого тиску Aussie Pumps AB Scud 40. Aussie Pumps AB Scud 40 16 сторінок. Stainless steel frames, 3,000/4,000 psi
Також для Aussie Pumps AB Scud 40: Інструкція з експлуатації (16 сторінок)
Feb 2019
Using Foamer
(supplied with AB30 hose reel version)
1. Using brass nipple supplied (C1500.06, M22 x
¼M), attach foaming nozzle to the gun in place of
Vario lance.
2. Prepare pressure washer detergent solution as
required by manufacturer.
3. Fill foamer bottle and screw into foamer nozzle.
Ensure siphon tube is attached inside bottle.
4. Spray angle can be adjusted by rotating the nozzle
cover. The amount of foam delivered is adjusted
with the knob on top.
5. Apply cleaning solution to a dry surface, starting at
lower portion of areas to be washed and work
upward, using long overlapping strokes.
6. Allow time for foam to activate and then rinse off.
DO NOT allow foam to dry on.
IMPORTANT: rinse foamer nozzle & bottle with clean
water after every use to prevent clogging.
FOAMER APPLIES DETERGENT TO DISOLVE GREASE
(applied at low pressure)
Aussie AB Direct Drive Super Scud Series ... Operation & Maintenance Manual
G.
Stopping the machine
1. If using the detergent injector, flush out the
chemical by running clean water through the
system.
2. Allow machine to run for 1 minute without load
to cool before stopping.
3. Turn engine ON/OFF switch to OFF
4. Pull recoil start until compression resistance is
felt. Store the machine in this position to help
prevent valve warpage or sticking.
5. Close fuel valve.
FAILURE TO CLOSE THE FUEL VALVE ON THE
ENGINE CAN CAUSE FUEL LEAKAGE WHEN THE
MACHINE IS BEING TRANSPORTED!
6. Turn off water supply.
7. Pull gun trigger to release all pressure in the
system, then LOCK THE TRIGGER.
8. Hoses may now be disconnected from the
machine.
Failure to release pressure before disconnecting the
hose quick coupler will result in the quick coupler o-
ring seal blowing out. This o-ring must be replaced
before operating machine.
CLEAN FASTER WITH A FLAT SURFACE CLEANER
Aussie Pumps
9