Datavideo TLM-702JF Інструкція з експлуатації - Сторінка 9
Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Контролер Datavideo TLM-702JF. Datavideo TLM-702JF 11 сторінок. Rs232 ethernet controller for se500
If the RMC150 fails to make contact with the SE500 you will see this warning.
You will also notice that the virtual buttons do not light up.
The most likely causes of this are:
You are not using the correct type of CAT 5 cable Crossover for connection directly between the RMC150
and a PC / Straight through for connection via a hub.
Your PC is not set to an appropriate IP Address. Go into network settings and set the IP address correctly.