STEP 5 - WORK IN RESTRAINED POSITION
Always maintain a three point of contact when climbing or descending the
ladder. As you move upwards, ensure the rope grab is moving up the rope with
you. If the rope starts to lift forming a loop in the rope, stop climbing and slide
the rope grab up so the rope is tight again.
Keep the rope as tight as possible and pull against the anchor, as this willreduce
the fall distance. Working in a work restraint technique is the safest way to
ensure a limited fall distance.
RESTRAINT TECHNIQUE
SYSTEM DESCRIPTION
A combination of anchorage placement and lanyard length adjustment which
will not physically permit the operator to reach a fall risk position unless the
lanyard is incorrectly adjusted. Control on a person's movement by use of
a fall- arrest system, which entails connection to an anchorage using an
adjustable lanyard or other components that can be adjusted for length
as necessary to physically prevent the person from reaching a position at
which there is a risk of a free or limited free fall.
REQUIREMENTS
Where any possible fall will only be a limited free fall (<600 mm):
1. A full-body harness
2. Anchorage with ultimate strength 15 kN
TYPICAL APPLICATION
Any situation where access to the work can be
achieved entirely on a working surface with secure
footing and without exposure to a fall, provided that
the equipment is correctly adjusted.
Take care when transferring to the roof.
Establish Restraint Technique position.
1300 100 120
8
AUSTLIFT ROOFER'S KIT
60°
Once Restraint Technique position
is established, work within a 60°
arc, avoiding pendulum swing falls.
www.austlift.com.au