Cookology TCH301 Інструкція з експлуатації - Сторінка 7

Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Варильна поверхня Cookology TCH301. Cookology TCH301 14 сторінок. 30cm ceramic hob black

Fitting guidelines
The ceramic hob is manufactured to work with one-phase
alternating current.The voltage rating of the ceramic hob
heating elements is 220-240V. Adapting the ceramic hob
to operate with two-phase current is possible by
appropriate bridging in the connection box according to
the connection diagram below. The connection diagram
is also found on the cover of the connection box.
Remember that the connection wire should match the
connection type and the power rating of the ceramic hob.
The connection cable must be secured in a strain-relief clamp.
Replacing the mains supply cable
 If the mains supply cable is damaged, then it must be replaced by an
appropriate replacement.
 The mains supply cable should be replaced in accordance with the
following instructions:
 Switch the appliance off at the
control switch.
 Open the terminal block on the
underside of the hob.
 Unscrew the terminal screws
fixing the cable.
 The "green-yellow" earth wire
must be connected to the terminal
marked
mm longer than the live and neutral wires.
 The "blue" neutral wire must be connected to the terminal marked
with letter (N) - the live wire must be connected to the terminal
marked with letter (L).
Description of the Ceramic hob surface layout
3.
. It must be about 10
7
2
1