BEFORE YOu START
ImPORTAnT!
1. Insert batteries for the main unit before doing so for the remote
sensor.
2. Place the main unit as close as possible to the remote unit.
3. Position the remote unit and main unit within the effective
transmission range.
When changing batteries always change batteries in the main unit as
well as all remote units and replace them in the correct order, so the
remote connection can be re-established. If batteries are exchanged
in only one of the devices (i.e. the remote sensor) the signal can't be
received or can't be received correctly.
Note, that the effective range is vastly affected by building materials
and position of the main and remote units. Due to external influences
(various RC devices and other sources of interference), the maximum
distance can be greatly reduced. In such cases we suggest to position
the main unit and the remote sensor at other places. Sometimes all it
takes is a relocation of one of these components of a few inches!
POwER SuPPlY
Main unit (Fig. 15)
1. Open the battery compartment door.
2. Install 3 batteries (AA size 1.5V) strictly according to the polarities
shown.
3. Reinsert the battery compartment door.
4. Once the batteries are inserted, all the segments of the LCD will be
shown briefly before entering the radio-controlled time reception
mode.
5. The RC clock will automatically start scanning for the radio-
controlled time signal in 8 seconds.
nOTE!
1. If no display appears on the LCD after inserting the batteries, press
the RESET knob by using a pointed object.
2. In some cases, you may not receive the signal immediately due to
the atmospheric disturbance.
Remote sensor (Fig. 16)
1. Open the battery compartment door.
2. Install 3 batteries (AA size 1.5V) strictly according to the polarities
shown.
3. Reinsert the battery compartment door.
nOTE!
1. Ensure the water tight O-ring is properly aligned in place to ensure
water resistant.
2. The red LED will begin flashing every 12 seconds.
low battery warning
When it is time to replace the batteries, the respective low battery
indicator
will be shown near to the time display (batteries for main
unit) or near to the outdoor temperature (batteries for remote sensor).
InSTAllATIOn
Remote sensor (Fig. 17-20)
Install the wireless 5-in-1 sensor in an open location with no
obstructions above and around the sensor for accurate rain and wind
measurement. Install the sensor with the smaller end facing the North
to properly orient the wind direction vane.
Secure the mounting stand and bracket (included) to a post or pole,
and allow minimum 1.5m off the ground.
Fig. 17/18: Mounting on pole (Pole Diameter 1" - 1.3" (25 - 33mm)).
Fig. 19:
Mounting on the railing.
Fig. 20:
Circular level.
Mounting guidelines:
1. Install the wireless 5-in-1 sensor at least 1.5m off the ground for
12
better and more accurate wind measurements.
2. Choose an open area within 150 meters from the LCD display Main
Unit.
3. Install the wireless 5-in-1 sensor as level as possible to achieve
accurate rain and wind measurements. A circular level device is
provided to ensure a level installation.
4. Mount the wireless 5-in-1 sensor with the wind meter end pointing
to the North to correctly orient direction of the wind vane.
Main station (Fig. 21)
Fig. 21
The unit is designed for desktop or wall mount for easy viewing.
Insert the stand so that the pins on the bottom side reach into the
indentions of the station.
The triangular notch on the backside of the main station can be used
to mount the device on walls with a wall screw (not included).
RECEIVInG mEASuREmEnTS AnD TImE SIGnAl
Once batteries are placed in the remote unit, it will start transmitting
temperature readings at roughly 45 second intervals. As soon as
batteries are installed in the main unit it will start searching for a signal
from the remote sensor for about 3 minutes. Upon successful reception
of the signal, the outdoor temperature will be displayed on the main unit.
The main unit will automatically update its readings at about 45 second
intervals.
Subsequently, the main unit will attempt to receive the DCF radio signal.
The reception symbol
flashes. When the time signal is received
after 3-5 minutes, the current time and date appear in the display. The
reception symbol will now be shown permanently in the display. Date
and time are automatically updated daily at 2:05 o'clock (CET) by the
main unit.
Manual pairing after battery change
Whenever you changed the batteries of the wireless 5-in-1 sensor,
pairing must be done manually.
1. Change the batteries to new ones.
2. Press and hold the SCAN button for 2 seconds.
3. Press the RESET button on the sensor.
nOTE!
1. Pressing RESET button at bottom of wireless 5-in-1 sensor will
generate a new code for pairing purpose.
2. Always dispose old batteries in an environmental safe manner.
DATA ClEARInG
During installation of the wireless 5-in-1 sensor, the sensors were likely
to be triggered, resulting in erroneous rainfall and wind measurements.
After the installation user may clear all the erroneous data from the
main unit without a need to reset the clock and re-establish pairing.
Simply press and hold the HISTORY button for 10 seconds. This will
clear out any data recorded before.
TImE SETTInG
The unit automatically set itself accordingly to the Radio Controlled
Clock signal it received. To set the clock/calendar manually, first
disable the reception by holding the RCC button for 8 seconds.
Manual time setting
1. Press and hold
button for 2 seconds until "12 or 24Hr" flashes.