Bresser 70-02510 Інструкція з експлуатації - Сторінка 6

Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Метеостанція Bresser 70-02510. Bresser 70-02510 13 сторінок. Weather center 5-in-1
Також для Bresser 70-02510: Інструкція з експлуатації (20 сторінок)

Bresser 70-02510 Інструкція з експлуатації
2. Use
or
button to adjust and press
the next setting.
3. Repeat step 2 for setting hours, minutes, seconds, year, month,
date, hour offset, language and daylight saving time (DST).
nOTE!
1. The unit will automatically exit setting mode if no button was pressed
in 60 seconds.
2. The hour offset is for DCF and MSF version. Its range is between
-23 and +23 hours.
3. The language options are English (EN), French (FR), German (DE),
Spanish (ES), and Italian (IT).
4. DST (Daylight Saving Time) feature is set to Auto (factory set). The
clock has been programmed to automatically switch when the
daylight saving time is in effect. User can set the DST to OFF to
disable the feature.
Disable / Enable RCC signal reception (Fig. 12)
1. Press and hold RCC button 8 seconds to disable the reception.
2. Press and hold RCC button 8 seconds to enable automatic RCC
reception.
Fig. 22
RCC signal on

AlARm ClOCK SETTInG

Turn on/off alarm clock (and ice-alert function) (Fig. 13)
1. Press
button to show the alarm time.
2. Press
button twice to activate the alarm.
3. Press
button three times to activate alarm with ice-alert function.
4. To disable the alarm, press
Fig. 23
alarm off
nOTE!
1. Press SNOOZE/LIGHT button when alarm sounds to interrupt the
alarm. The alarm will then start again after 5 minutes.
2. Pres
button when alarm sounds to deactivate the alarm until
next time.
Alarm time setting
1. Press and hold
button for 2 seconds to enter alarm setting mode.
Hours will begin to flash.
2. Use
or
button to adjust the desired value and press
to proceed to set minutes.
3. Repeat step 2 to set minutes, then press
nOTE!
Press
button twice when alarm time is being displayed will activate
the temperature-adjusted pre-alarm (ice-alert). The alarm will sound
30 minutes earlier if it detects outside temperature is below -3°C.

wEAThER FORECAST

The device contains sensitive pressure sensor built-in with
sophisticated and proven software that predicts weather for the next
12 hours.
Fig. 24
sunny, clear
slightly cloudy
cloudy
nOTE!
1. The accuracy of a general pressure-based weather forecast is
button to proceed to
RCC signal off
button until the alarm icons disappear.
alarm on
alarm and ice-alert on
button to exit.
rainy
rainy, stormy
about 70% to 75%.
2. The weather forecast is meant for the next 12 hours, it may not
necessarily reflect the current situation.
3. The "Snowy" weather forecast is not based on the atmospheric
pressure, but based on the outdoor temperature. When the outdoor
temperature is below -3°C (26°F), the "Snowy" weather indicator
will be displayed on the LCD.

BAROmETRIC / ATmOSPhERIC PRESSuRE

Atmospheric Pressure is the pressure at any location of the Earth
caused by the weight of the column of air above it. One atmospheric
pressure refers to the average pressure and gradually decreases
as altitude increases. Meteorologists use barometers to measure
atmospheric pressure. Since variation in atmospheric pressure greatly
affected by weather, it is possible to forecast the weather by measuring
the changes in pressure.
Select display mode
1. Press and hold
pressure setting mode.
2. Use
or
atmospheric pressure:
• ABSOLUTE the absolute atmospheric pressure of your location
• RELATIVE the relative atmospheric pressure based on the sea level
Set relative atmospheric pressure value
1. Get the atmospheric pressure data of the sea level (it is also the
relative atmospheric pressure data of your home area) through the
local weather service, internet and other channels.
2. Press and hold
RELATIVE flashes.
3. Press
or
button to switch to RELATIVE mode.
4. Press
button again until the number for RELATIVE flashes.
5. Use
or
button to change the value.
6. Press
button to save and exit the setting mode.
nOTE!
1. The default relative atmospheric pressure value is 1013 mb/hPa
(29.91 inHg), which refers to the average atmospheric pressure.
2. When you change the relative atmospheric pressure value, the
weather indicators will change along with it.
3. The built-in barometer can notice the environmental absolute
atmospheric pressure changes. Based on the data collected, it
can predict the weather conditions in the forthcoming 12 hours.
Therefore, the weather indicators will change according to the
detected absolute atmospheric pressure after you operate the
clock for 1 hour.
4. The relative atmospheric pressure is based on the sea level, but it
will change with the absolute atmospheric pressure changes after
operating the clock for 1 hour.
button
Select barometer measurement unit
Press
button several times until the desired measurement unit is
displayed: inHg, mmHg or hPa.
TEmPERATuRE & humIDITY
Comfort Indication
The comfort indication is a pictorial indication based on indoor air
temperature and humidity in an attempt to determine comfort level.
Fig. 25
too cold, too dry
hInwEIS!
1. Comfort indication can vary under the same temperature, depending
on the humidity.
snowy
2. There is no comfort Indication when temperature is below 0°C
(32°F) or over 60°C (140°F).
button for 2 seconds to enter atmospheric
button to select between absolute and relative
button for 2 seconds until ABSOLUTE or
comfortable
too warm, too humid
13