CAPACITIVE MANUAL SWITCH
The capacitive manual control switch is operated by touching
the wood surface directly in front of the lift column flap.
Before starting the system, you must reset the control unit.
Reset:
Tap five times, and after the fifth time leave your finger on
the surface until the lift column reaches the bottom positi-
on. When it reaches the bottom position there will be a beep
signal. The device is now ready for operation.
Up:
Tap twice, and after the second tap leave your finger on the
surface until the monitor moves in the desired direction. The
lift column automatically moves to the top position.
Down:
Tap twice, and after the second tap leave your finger on the
surface until the monitor moves in the desired direction. The
lift column automatically moves to the lower position.
Stop:
Tap once – the lift column stops. The down/up function swit-
ches after each stop.
AUTOMATICALLY TURNING THE MONITOR ON AND OFF:
Connect the coupler provided in the assembly package to the
control unit to automatically activate it.The power supply is
activated ca 50 mm above the lowest monitor position. The
power supply remains activated as long as the monitor is at
least 50 mm below the highest monitor position. The control
unit deactivates the power supply after one minute due to
safety reasons, if the monitor lift is not fully extended (e.g.
only half upward lift) to avoid heat accumulation and resulting
damage to the device.
9