This product accepts digital control signals in protocol DMX512(1990).The
amount of lighting fixtures connected in parallel is no more than 32.Connect the
DMX controller's Output to the first lighting fixture's Input cable with a 2 core XLR
signal cable(Shown as above ),connect the first lighting fixture's Output cable to the
second lighting fixture's Input cable and connect the rest light fixtures in the same
way.Eventually,connect the last lighting fixture's Output cable to a DMXterminator
Under DMX-512 signal control mode,the last lighting fixture's DMX Output must be
connected with a DMX terminator.This prevents electrical noise from disturbing and
corrupting the DMX control signals.The DMX terminator is simply an XLR
connector with a 120Ω(ohm) resistor connected across pins 2 and 3,which is then
plugged into the output socket on the last projector in the chain.Then connections are
illustrated above.
ILDA control signal connection method:
Connection built through product male/female DB 25 degree socket.Like above
picture. In addition to the above connections, ILDA signal cannot be connected in any
other way