Hi-Z Antennas 4-8 PRO Посібник - Сторінка 8

Переглянути онлайн або завантажити pdf Посібник для Антена Hi-Z Antennas 4-8 PRO. Hi-Z Antennas 4-8 PRO 15 сторінок. Up 8 element circle array

Fig. 5
1. Run equal lengths of RG6 from the Hi-Z 4-8PRO PnP controller to each vertical. This connects to the Hi-Z 4-8PRO PnP
controller Ant 1-8 to verticals 1-8. Be certain to observe these connections based on the orientation or placement of
verticals for correct aiming. Fig. 5 & Fig.6 These cables MUST be the same length as currently installed with the Hi-Z 4.
2. Connect the Hi-Z supplied short and long Delay cables at Short Delay and Long Delay connectors on the Hi-Z 4-8PRO
phase controller. Fig.7
Connect the factory supplied 2 foot wire jumper with fork terminals from either of the 13.8VDC terminals on the controllers
and connect the other end to the 13.8VDC terminal on the75Ω In-line pre-amp.
Connect the factory supplied 2 foot RG6 cable from the OUTPUT of the Hi-Z 4-8 phase controller (Fig.4) to the input connector
on the in-line pre-amp. See Fig. 8
Connect the 13.8VDC and GND from the phase controller to the PnP controller (2ft long wires, supplied with system).
Hi-Z 4-8PRO UP Manual V1.0
Fig. 7
©2011 Hi-Z Antennas™
Fig.6
www.hizantennas.com
8