ADEMCO LYNXR Series Посібник із швидкого старту - Сторінка 3
Переглянути онлайн або завантажити pdf Посібник із швидкого старту для Система безпеки ADEMCO LYNXR Series. ADEMCO LYNXR Series 8 сторінок.
TO PREVENT RISK OF SHOCK
DISCONNECT TELEPHONE LINE
AT TELECOM JACK BEFORE
RJ11
TO
HANDSET
PHONE
LINE
LOCAL SOUNDER
DISABLE SHUNT
REMOVE TO
DISABLE
THE LYNX SERIES CONTROLS ARE
EQUIPPED WITH AN INTEGRAL
RECHARGEABLE BATTERY PACK.
LYNXR:
LYNXR24:
LYNXR-EN:
REPLACE EVERY FOUR YEARS
System Programming
!
Certain features differ between the LYNXR/LYNXR24 and the LYNXR-EN models. Verify the specific model being
installed prior to the system programming.
Step
1.
Set a programming default as follows:
a.
Enter Programming mode: Installer Code + 8 0 0.
b.
Press *97, then press a number 1-4 to select a default table from the tables listed on page 1.
Program the variable data fields as follows:
2.
a.
RF House ID - Press *24, then enter the desired 2-digit RF House ID for wireless keypads.
b.
PABX Access Code (if used) - Press *40, then enter up to 6 digits. If fewer than 6 digits are used, press [*] to
end the field and advance to the next field.
c.
Primary Phone Number - Press *41, then enter the primary phone number, up to 20 digits. If fewer than 20
digits are used, press [*] to end the field and advance to the next field.
d.
Secondary Phone Number (if used ) - Press *42, then enter the secondary phone number, up to 24 digits. If
fewer than 24 digits are used, press [*] to end the field and advance to the next field.
e.
Secondary Account Number (if used) - Press *44, then enter the secondary account number. If only 3 digits
are used, press [*] to end the field and advance to the next field.
f.
Pager Characters - Press *88 if using Default Table 2 or 4, then enter up to 16 digits which may be required
by your pager service (e.g. account number, PIN, etc.). If fewer than 16 digits are used, press [*] to end the
field and advance to the next field.
g.
Download Phone Number - Press *94, then enter the downloading computer phone number, up to 20 digits.
If fewer than 20 digits are used, press [*] to end the field.
ALL OUTPUT CIRCUITS ARE POWER LIMITED.
WARNING:
SERVICING THIS UNIT.
EARTH
GROUND
PHONE
8
1
2
3
4
5
POS
JACK
TIP
RING
TIP
RING
INCOMING
PHONE
LINE
INCOMING
TELEPHONE
LINE
EARTH
PREMISES
GROUND
TELEPHONE
WEEKLY TESTING IS
REQUIRED TO ENSURE
P/N LYNXRCHKIT-SC
PROPER OPERATION
P/N LYNXRCHKIT-HC
OF THIS SYSTEM
P/N LYNXRCHKIT-SC
OR
P/N LYNXRCHKIT-HC
LYNX-R-SERIES WIRING CONNECTIONS
AAV / LRR
TRIGGER
(LYNXR/LYNR24)
LRR
TRIGGER
ZONE
(LYNXR-EN) SOUNDERS
11
12
6
7
8
9
10
(+)
( )
( )
(+)
( )
(+)
HARD
WIRED
ZONE
TRIGGER
SIGNAL
(NEG)
PIEZO
BELL
2k OHMS
6-14VDC
30mA max.
EOLR
6-14VDC
120mA max.
(e.g. WAVE2EX)
NOTE
USE ONLY 1332/1332X10 OR 1332CN
TRANSFORMERS PROVIDED
Action
-3-
PLCD
AC
13
14
15
16
DATA
SYNC
OUT
IN
1332/
1332X10/
1332CN
PLUG-IN
TRANSFORMER
9VAC, 15VA
AC
AC
SYNC
COM
DATA
1332X10
ONLY
CONNECTIONS
01009-009-V0