1. Remove the two Phillips head screws
which secure the cover to the cover-
plate assembly.
2. Remove the eight pairs of nuts and
bolts which hold the coverplate assem-
bly to the housing. (Figure 1) Note the
position of the reset button.
3. Rotate the coverplate assembly and
counter to the desired orientation.
Make sure the flow arrow in the
housing points toward the outlet port.
(Figure 2)
4. Make sure the housing O-ring is fully
seated and firmly tighten the eight nuts
and bolts which secure the coverplate
assembly.
5. Place the reset button in position. Secure
the cover to the coverplate assembly
with the two Phillips head screws.
Meter Installation
1. Remove protective plugs from the
meter inlet and outlet ports.
2. Wrap threaded male connections with
®
Teflon
tape or use a pipe sealant com-
pound compatible with petroleum
fuels. We recommend Lock-Tite thread
sealant at the inlet fitting in horizontal
orientation.
3. Install the meter on the pump using an
appropriately sized nipple. The meter's
flow path is marked on the housing
exterior with an arrow pointing toward
the outlet port.
4. Install other system components on the
meter and tighten snugly.
Figure 1
Before use, review the safety instructions
given above. Visually check the meter to
ensure it is securely connected to other sys-
tem components and there is no leakage.
Promptly wipe spilled fuel from the meter's
exterior and other system components.
The large meter display represents the
Batch Total for each fuel delivery. Before
dispensing, reset the Batch Total to zero
by pushing the reset button. (Figure 3)
Figure 2
The small display represents the Cumula-
tive Total of all fuel deliveries and cannot
be reset.
The meter is accurately calibrated at the
factory for use with diesel fuel. Due to dif-
ferences in viscosity and flowrates, the
meter may require recalibration to measure
other fuels or to adjust for inaccuracies.
1. Purge air from the meter and fuel sys-
tem by dispensing fuel into a container
until a full flow occurs. Close the
nozzle.

OPERATION

CALIBRATION

Figure 3
2