Days EQUALIZER SYSTEMS AM Series Посібник з монтажу та експлуатації - Сторінка 2

Переглянути онлайн або завантажити pdf Посібник з монтажу та експлуатації для Валети. Days EQUALIZER SYSTEMS AM Series. Days EQUALIZER SYSTEMS AM Series 7 сторінок.

The AM Jack has been shipped with all necessary Switchgear, Harnesses and Hydraulic Lines.
These items are specifically engineered to operate your System and should not be altered in any
manner. Modification of any factory supplied item may result in the denial of all warranty claims.
Switchgear
The Unit may
have been provided with a key switch in the switchgear box (depending on the option
ordered).
If unit is not supplied with a key switch, the +12v battery lead must be fed through a power
disconnect switch to fully isolate the system during travel or inactivity. Minimum disconnect switch rating
must be Minimum 100 ampere DC. Switchgear is plugged into the system harness through a weather
resistant connector (shown in Fig.1)
Battery Connections
Pumps #'s 2142, 2390, 2532, 3126, 3170:
Battery Lead (+12volts): Attach a # 4 gauge wire between the positive (+12V) terminal on the
battery and the large post on the solenoid opposite the black motor wire on the solenoid. If circuit
protection is required, Install an 80 amp (minimum) circuit breaker.
Battery / Pump Ground (-12volts): Attach a # 4 gauge wire between the negative (-12v) terminal
on the battery and the ground stud located directly in front of the motor. It is not acceptable to allow
the Jack mounting bolts or the weld to be the sole grounding connection.
Pump #'s 3040, 3041, 3200, 3201 and 3201KS see Fig. 2
Attach a minimum # 6 gauge wire between the positive (+12V) terminal on the battery and the plus ( + )
terminal on the contactor. Attach a minimum #6 Gauge wire between battery negative ( - ) and the
negative terminal on the contactor. Note: These units will not ground thru the mounting. The described
ground/negative battery to contactor connection must be made.
Fig. # 2: Pictured
Pump #'s, 3040, 3041,
3200, 3201 and 3201KS
Switch Harness and Hydraulic Lines
Fig.1- Weather Resistant Connector
Attach battery negative
(ground) to
contactor here
(6 gage min)
Attach +12V
Positive from Power Supply
(6 gage min)