If your unit is not equipped with the override hand pump, it is operated as
follows: Pump #'s 2390, 2532, 3040, 3041,3043, 3200, 3201, 3201KS
1/4 " (6mm) Allen Drive Hex Key or 7/16 " (11mm) Hex Head Socket
Your hydraulic motor is equipped with a manual override output shaft. The drill must be capable
of producing a minimum of 2000 rpm for the pump to develop appropriate pressure output.
To Retract your Jack: Uni-Rotational Pump # 2142, 3126, 3170
1. Locate the red knurled knob on the directional valve; this valve will be on the side of the
manifold. Pull the red knob out and turn 1/4 turn. The knob will remain in the "Out"
position. Do not use anything other than your fingers to manually shift the directional
valve.
2. Remove the black plastic cap
the proper size hex bit on the manual override shaft located at the top of the motor. Run
drill in a clockwise direction at 2000 rpm (minimum). The jack
3. When retraction is complete, return the directional valve to the normal position. Reinstall
black plastic cap / silver seal on motor end.
Caution: Following manual override operation, failure to return all valves to normal
position may result in one or more jacks drifting down from their retracted (stowed)
position. For directional valves, rotate the red knob until it "snaps" back to the normal
position.
Note: The normal operating position of the red knob on the directional valve is the "in" position.
The only time the valve should be shifted manually is when attempting to operate jack via manual
override.
To Extend Your Jack:
1. To extend the jack, follow all of the above steps Except Do Not manually shift the
directional valve as described in step #3 above.
Manual Override – Output Shaft
/ silver seal
from the top of the motor. Place the drill with
(s)
will retract.