WIRING CONNECTIONS
MOUNTING THE No. 4127
CONSOLE(S)
(See Summery of Connoetfons Dlmgmm)
Important:
Do not connect the battery or plug in the AC
transformer until all other wiring connections have been
completed. When pownrbrg up the systsm, ysu must uas
tb foIlswIng ssqusnssz
1. Plug in transformer.
2. Connect the batten.
Grounding
the System
In order for the protective devices in this product to be effective,
Terminal 21 must be terminated in a good earth ground. The
following are examples of good eanh grounds available at most
installatiins:
Metal Cold Water Pipe: Use a noncorrosive metal strap firmly
secured to the pipe to which the ground lead is electrically
connected and secured.
AC Power Outlet Ground: Available from 3 prong, 125VAC.
power outlets only. To test the integrity of the ground terminal,
use a three-wire circuit tester with neon lamp indiirs,
such as
the UL-Listed Ideal Model 61935, or equivalent, available at
most ebctrbal supply stores.
1.
2.
3.
4.
5.
6.
Separate the consob from its bad@ate by removal of the two
screws on the tap and bottom edges.
Use the backplate to mark the positions on the wall for the
screw mounting holes and the cutout fqr the interface wiring.
Use wall anchors for the screws and make the cutout in the
wall no larger than indicated on the template. The backplate is
designed to be directly mounted to either a single or double
gang ebctrbal bow.
Pull the interface wiring in the wall through the cut-out.
Pass the interface wiring through the opening in the ba&plate
and then mount backplate to the wall surface with screws.
Splice the interface wiring to the console wires. Insulated
solderless wire splices (such as Ademco No. 311) may be
used for splicing.
Attach the main body of the console to the wall-mounted
bsckplate. The oonsole is properly attached when it is screwed
tothebackp&ebytopandbottomscrews.
PROGRAMMING
THE SECURITY CONTROL
Installer options are stored in non-removable, electrically'
erasable, non-volatile EEROM memory. 'These options must
be programmed for the particular installation to establish its
specifii alarm and repolting features. The security control may
be programmed from a remote console.
When pmgramming, the field number will be displayed on the
LCD diiy;
also. each entry is displayed as it is keyed in. After
programming, values that have been entered in each fiikt can
berevbwedand,il
necessary, mod&d.
*Note: It Is possibb to program the system at any time - even
at the installeti premises prior to the actual installation.
Simply apply power temporarily to the control and then
program the unit as desired.
When programming from the consoles note the folbwing:
1. Enter the -ramming
mode by simultaneously depressing
the r] and [W] keys wlthout 30 ssoonds after power Is
rpplbd
to the Control, or subsequently by keying the code
4+1+2+Ofolknr&bvde~essionofCODE+O+Okevs.
Once an installer code & p&rammed, use it instead of ihe
default c#le (4120) to gain access to the programming mode.
2~secondsafterenlyintotheprogrammode.Wwillbe
displayed. Following the above display, the system is ready
to awept entrbs for Address 00.
3.To pmgram a data field, key [.I plus Addnu
(for example.
l
Ol), then make the required entry. To simply review a data
fiikf. key [a) plus Address.
4.When a data field has been completely programmed, the
console will 'beep' three times and then automatically
proceed to, and display. the next data field address to bs
programmed if that field is the next sequential address (if not,
key k] plus the address of the next field to be programmed.
5. II the number of diits that you enter in the data field is less
than the maximum permitted (for example, phone number),
then the console will display the last data entered. To
proceed, the next dsta fiild address to bs programmsd must
then be entered (for example. %5).
6. If an address Is bnproperly entered, the console will display
FC. II a program entry is improperly entered (for example, a
larger number than that which is permitted), the console
display will go blank. In either case, simply re-enter the
number.
ENTER
1. POWER UP, then depress p] and [#J
PROGRAMMING
simultaneously
within 30 seconds of
MODE:
powering up.
OR
2. Initiilly, Key: 4 + 1 + 2 + 0 plus CODE
key+O+O.
OR
3.After Installer Code is programmed.
key: Inataller Code + CODE key +O+O.
Notea: Type 3 method of re-entry to the pro-
EXm PROGRAM-
MING MODE:
l 99
giamming
mode is inhibited
if -the
programming mode is exited via use of
l a6.
Type 1 method of entry can always be
used, unless console program-ming has
been locked
out by the remote
downbader.
(always albws m-entry to program-ming
mode via Type 3 entry method above),
unless console programming has been
locked out by the remote downloader).
'98 (inhibits resntry to programming mode
via Type 3 entry method).
Note: When the programming mode is exited,
RESTORE
FACTORY DFLT
AfXANCE TOFIELD:
'96
[*]+ADDRESS (e.g., 01.10.21 etc)
PROGRAM FIELD:
ERASE FIELDS:
READ FIEU):
(*]+ACORES$folbvmd by dataenttfg
(.]+ADDRESS+[.]
(only applies to
Addresses 31 thru 35).
[#I + ADDRESS
SPECfAL MESSAGES
OC = OPEN CIRCUlT (no communicatiin between the Console
and the Control).
FC I FtELD CODE ERROR (program entry m'&ake, reenter
the data).
NOTE: The following programming information contains the
factory default settings within the brackets [ 1.
a 1 minute set-up period must elapse
before the system can properly function.
7