Model 262-001 and 272-001 Intrinsically-Safe Telephones
Installation

Installation Guidelines

When installing any GAI-Tronics telephone equipment, please adhere to the following guidelines to
ensure the safety of all personnel:
NEVER install telephone wiring during a lightning storm.
Install a UL Listed lightning arrestor on any phone installed where the phone or phone cable is at
risk of being exposed to lightning strikes. The lightning arrestor must be installed as close to the
phone as possible to maximize the protection. The lightning arrestor must not be installed within the
enclosure supplied with the phone.
NEVER install telephone jacks in wet locations unless the jack is specifically designed for wet
locations.
NEVER touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
USE CAUTION when installing or modifying telephone lines.
Install UL Listed telephone line suppressor (customer-supplied) on the telephone line.
Use silicone sealant or equivalent around and inside all conduit entries