DBK Drymatic Boost Bar FGPH109 Інструкція з експлуатації - Сторінка 14
Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Сушарка DBK Drymatic Boost Bar FGPH109. DBK Drymatic Boost Bar FGPH109 16 сторінок. Adaptable heat drying system
Також для DBK Drymatic Boost Bar FGPH109: Інструкція з експлуатації (18 сторінок)
Troubleshooting:
In the event of a fault the first thing to try is to switch off the machine, remove the plug from the electrical outlet, and then
wait ten seconds. You can then plug it back in and turn it on again, and see if there are any improvements. If not please refer
to this troubleshooting table for causes and solutions.
Fault
No power, red power switch is not
illuminated when in on position.
No display, red power switch
illuminates when in on position.
Unit not producing warm airflow. Fan
symbol is marked with a X
Unit not producing hot air. No
Rotating graphic is shown in hours
display.
Drymatic Wall and Floor System not
inflating
In the event that this list does not cover your particular issue or the solution does not solve the
problem please contact your local Drymatic representative.
Cause
1) Plug fuse blown.
2) Fault with electrical outlet or
power cord.
1) Internal fuse blown.
1) Insufficient airflow
1) Machine has not had sufficient
time to heat up.
2) Temperature setting is lower than
room ambient.
1) Insufficient airflow
Solution
Check plug fuse, if plug type doesn't have a
fuse contact service.
Check electrical output and check cord for
any damage, breaks or cuts. If cord is
damaged seek replacement.
Check Internal fuse, it is located on the
switch panel next to the red power switch.
Replace if necessary.
Try positioning the air mover closer to the
Drymatic Boost Bar or use a higher speed
setting. Check that the air mover meets the
minimum requirements.
The machine will check for stable airflow
before gradually ramping up power. This
can take up to five minutes.
Increase the temperature setting, it may
be that the room is hotter than the
temperature limit set.
Try positioning the air mover closer to the
Drymatic Boost Bar or use a higher speed
setting. Check that the mat is well sealed
around the Drymatic Boost Bar and free to
inflate.
The
minimum
airflow of 650cfm (1100m³/hr) is the
requirement for the Drymatic Boost Bar to
function
correctly.
Inflating
depending on configuration, may require
significantly more airflow.
recommended
mats,