Galvin Specialised 170.81.11.00 Інструкція з монтажу виробу - Сторінка 3

Переглянути онлайн або завантажити pdf Інструкція з монтажу виробу для Сантехнічний виріб Galvin Specialised 170.81.11.00. Galvin Specialised 170.81.11.00 4 сторінки. Remote electronic drinking bubbler tap - battery

3. Fit Piezo Button
Install piezo button and connect it to the
electronic control unit.
Water
Supply
Solenoid
Coil
5. Fit Solenoid and Outlet
Fix the solenoid in position ensuring that
the solenoid coil is not facing
downwards.
Fit flexi hose to solenoid and water supply.
Fit flexi hose to outlet
4. Connect, Solenoid and Battery
Connect Piezo button, the solenoid and the battery to
the eletronic control unit.
The unit was supplied with 2 x 3.2metre extension
leads for connecting to battery and solenoid.
6. Testing
Once the drinking tap has been installed and tested
for leaks, the water height may be adjusted to suit the
available pressure .
− To adjust water flow (if required)
1. Remove the blanking screw
2. Adjust the water flow by turning the regulating
screw
3. Replace blanking screw
Note: The full range from minimum flow to
maximum flow is only ¼ turn
th
Version 1,15
March 2021, Page 3 of 4
Regulating
Screw
Blanking
Screw