MAINTENANCE & ADJUSTMENTS
tight and should be adjusted by turning the Adjustment knob counter clockwise to open the
gap between the jaws. The clamp jaws should be cleaned periodically to be free from dirt, oil,
and any string coating for them to grip properly.
NOTE: Due to the bearings used in the Clamp Lever the action of the Clamp Lever is
very light making it easy to apply excessive clamping pressure. Clamps that are set
too tight can damage the string as well as the string clamp jaws.
String Clamp Adjustment
The string clamps will need minor adjust-
ments according to string type, construction,
and gauge.
To adjust the gap (clamping pressure)
between the clamp jaws, insert the string
through the racquet as if you were beginning
the main strings. Clamp the string and pull
tension. If the string slips through the jaws of
Adjustment
Knob
the clamp, tighten the clamp by compressing
the clamp jaws together by hand while turn-
ing the Adjustment Knob, in the clockwise
direction. If the clamp leaves impressions or
damages the string, it may be excessively
Switch Action Clamp Base Adjust-
ment
If the Switch Action clamp bases slip on the
turntable, the base locking levers may need
adjusted. Turn the hex screw clockwise to
tighten the clamp and counterclockwise to
loosen. If frequent adjustment is needed,
remove the adjustment screw and tighten
the two screws underneath of the clamp.
Re-install the adjustment screw.
Switch Action Clamp Base Removal
If the Switch Action clamp base needs to be
removed, undo the 2 screws holding the FRP
stop, underneath of the turntable. Remove
the FRP stop and clamp for cleaning, adjust-
ment or replacement.