Decko 24000-DKO Посібник користувача - Сторінка 12

Переглянути онлайн або завантажити pdf Посібник користувача для Відкривач гаражних дверей Decko 24000-DKO. Decko 24000-DKO 14 сторінок. Handles doors 18 ft. wide & up to 7ft.tall

Wiring Instructions

!
To prevent SERIOUS INJURY or DEATH from electrocution:
- Power MUST NOT be connected until instructed.
- NO exposed part of the wire should be visible outside of the terminal for proper connection.
Open
Wire Terminals
Screwdriver or similar tool
Fig. 1
Insert into unit
Outside
1/2"
Actual size
Fig. 2
Fig. 3
12
WARNING
In the following section, the Photo Eye Safety System will
be connected to the Opener. Please read and understand
the wiring instructions before connecting wires.
1.
The connection terminals on the rear panel of the Opener
are used to connect wires from accessories.
2.
To connect a wire to an assigned terminal, use a small "flat
head" screwdriver to push in the orange tab on the Wire
Terminal as shown in Fig.1.
3.
Insert approximately 1/2" (13mm) of the wire into the
terminal while pushing in the tab as shown in Fig.2.
4.
Wires MUST NOT be frayed and connected properly as
shown in Fig.3. Each accessory requires a pair of
terminals, Each pair of terminals MUST be connected with
one white wire and one striped wire (non-polarized) from
the SAME accessory.
5.
Check for proper connection by gently pulling on the wire.
The wire should not come out of the terminal. NO exposed
part of the wire should be visible outside of the terminal.
6.
Use the insulated staples provided to secure the wires to
the wall and/or ceiling. Be careful not to damage the wires
while securing the staples.
Wires to the terminals on the Opener
Min. 5 feet (1.5m)
above floor
Photo Eye Safety System
Suggested placement of insulated staples
Force Adjustment
To prevent SERIOUS INJURY or DEATH from improper Force Adjustment:
- DO NOT adjust force to compensate for binding or sticking of the garage door. Call a qualified garage
door service technician to make necessary adjustments in case of binding.
- DO NOT increase the force beyond minimum force required for closing the door. Too much force will cause
improper operation of safety reversal mechanism.
- If either the Force or Travel limit adjustment is made, the other adjustment may also needed.
- After ANY adjustments, the Safety Reverse Test MUST be performed to ensure the door reverses on
contact with a 1-1/2" thick object (2x4 laid flat) .
For safe operation, the force setting should
always be set at the MINIMUM FORCE
required to run the door.
Terminals
Wall Panel
WARNING
!
Adjusting Force
1. Force Adjustment controls are located on the rear panel of
the Opener. The force adjustments regulate the amount of
force required to open or close the door.
2. Force Adjustment is applied only to compensate for the minor
resistance caused by weather or other means.
 Note: Force is preset at level 6 for both Open and Close
adjustments. The size and operating conditions of the
garage door will determine the correct level of Force/
Sensitivity. Weather conditions may also affect the operation
of the door requiring further adjustments as needed.
 Note: If the close force is set too light the Opener will reverse
the door during closing. If the open force is set too light the
Opener will stop the door during opening.
 Note: There are 12 levels for open and close force settings.
When either the maximum or minimum level is reached, the
light will flash 6 times.
 Never adjust the force setting by more than 1 level (1 press)
at a time.
Setting Force
Setting Close Force
1. If the door completes a full close cycle without reversing,
decrease (-) the Close Force by 1 level at a time until the
door reverses. If the door reverses during closing, increase
(+) Close Force by 1 increment. The Close Force is now
properly adjusted.
2. During the "door-close" cycle, the Opener will reverse if the
force required to close the door is exceeded.
Setting Open Force
1. If the door completes a full open cycle without stopping,
decrease (-) the amount of force by 1 level until the door
stops during the opening. Once the door stops during
opening, increase (+) Open Force by 1 increment. The Close
Force is now properly adjusted.
2. During the "door-open" cycle the Opener will stop if the force
required to open the door is exceeded.
17